577352
16
Zoom out
Zoom in
Previous page
1/40
Next page
16
GB
! Before operating your new appliance please read
this instruction booklet carefully. It contains important
information concerning the safe installation and operation
of the appliance.
! Please keep these operating instructions for future
reference. Make sure that the instructions are kept with
the appliance if it is sold, given away or moved.
! The appliance must be installed by a qualified
professional according to the instructions provided.
! Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected from
the electricity supply.
Room ventilation
The appliance may only be installed in permanently-
ventilated rooms, according to current national legislation.
The room in which the appliance is installed must be
ventilated adequately so as to provide as much air as is
needed by the normal gas combustion process (the flow
of air must not be lower than 2 m
3
/h per kW of installed
power).
The air inlets, protected by grilles, should have a duct
with an inner cross section of at least 100 cm
2
and should
be positioned so that they are not liable to even partial
obstruction (see figure A).
These inlets should be enlarged by 100% - with a
minimum of 200 cm
2
- whenever the surface of the hob
is not equipped with a flame failure safety device. When
the flow of air is provided in an indirect manner from
adjacent rooms (see figure B), provided that these are
not communal parts of a building, areas with increased
fire hazards or bedrooms, the inlets should be fitted with
a ventilation duct leading outside as described above.
A B
! After prolonged use of the appliance, it is advisable to
open a window or increase the speed of any fans used.
Disposing of combustion fumes
The disposal of combustion fumes should be guaranteed
using a hood connected to a safe and efficient natural
suction chimney, or using an electric fan that begins
to operate automatically every time the appliance is
switched on (see figure).
! The liquefied petroleum gases are heavier than air and
collect by the floor, therefore all rooms containing LPG
cylinders must have openings leading outside so that
any leaked gas can escape easily.
LPG cylinders, therefore, whether partially or completely
full, must not be installed or stored in rooms or storage
areas that are below ground level (cellars, etc.). Only the
cylinder being used should be stored in the room; this
should also be kept well away from sources
of heat (ovens, chimneys, stoves) that may cause
the temperature of the cylinder to rise above 50°C.
Positioning and levelling
! It is possible to install the appliance alongside
cupboards whose height does not exceed that of the
hob surface.
! Make sure that the wall in contact with the back of the
appliance is made from a non-flammable, heat-resistant
material (T 90°C).
To install the appliance correctly:
Place it in the kitchen, dining room or the bed-sit (not
in the bathroom).
If the top of the hob is higher than the cupboards, the
appliance must be installed at least 200 mm away from
them.
If the cooker is installed underneath a wall cabinet, there
must be a minimum distance of 420 mm between this
cabinet and the top of the hob.
This distance should be increased to 700 mm if the
wall cabinets are flammable (see figure).
Do not position blinds behind the cooker or less than
200 mm away from its sides.
A
Fumes channelled through
a chimney or branched
flue system reserved for
cooking appliances)
Installation
Adjacent room
Room requiring
ventilation
Ventilation opening for
comburent air
Increase in the gap between
the door and the flooring
Fumes channelled
straight outside
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Indesit I5GS1G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Indesit I5GS1G in the language / languages: English, Dutch, French as an attachment in your email.

The manual is 2,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info