647457
8
Zoom out
Zoom in
Previous page
1/48
Next page
8
ELECTRICAL CONNECTION
This unit is manufactured for a polarized, grounded 120 or 240 volt/60Hz. Electric power ab-
sorption of each model are shown in the Electrical and Gas Power Table enclosed.
Before connecting the appliance to the electric network, follow the instructions below:
1. fuse and electric feeding installation of your home must support the load of the appliance (see registration label).
2. Power supply system must have an ef cient earth plate.
3. The outlet or multiple-switch, with a minimum1/8” (3mm) contact opening, has to be easily reached once the
appliance has been installed.
The appliance is supplied without outlet: you need a normal one proper for the electric load.
The power supply cable should not reach a 120°F temperature above the one surrounding.
GAS CONNECTION
All gas connections must be made according to national and local codes. This gas supply (ser-
vice) line must be the same size or grater than the inlet line of the appliance. This range uses a
½”NPT inlet. Sealant on all pipe joints must be resistive to LP gas.
1. Manual Shut-off Valve: This installer-supplied valve must be installed in the gas service line ahead of the appliance
in the gas stream and in a position where it can be reached quickly in the event of an emergency. The manual
shut-off valve shall be installed properly in order to be accessible when appliance is installed in de nitive position.
In Massachusetts: A ‘T’ handle type manual gas valve must be installed in the gas supply line to this appliance.
2. Pressure Regulator
1. All heavy duty, commercial type cooking equipment must have a pressure regulator on the incoming service line
for safe and ef cient operation, since service pressure may uctuate with local demand. The pressure regulator is
supplied separately with the appliance; regulator has two female threads ½” NPT; it shall be installed properly in
order to be accessible when appliance is installed in de nitive position.
2. This range can be used with Natural or LP/Propane gas. It is shipped from the factory adjusted for use with natural
gas. The ori ce hoods must be screwed snug when LP/Propane gas is used(see LP/Propane conversion).
3. The appliance, its individual shut-off valve, and pressure regulator must be disconnected from the gas supply
piping system during any pressure testing of that system at pressure is in excess of 1/2psig(3.45kPa).
4. The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve
during any pressure testing of gas supply piping system at test pressures equal to or less than 1/2psig(3.45kPa).
3. Flexible Connections:
1. If the unit is to be installed with exible couplings and/or quick disconnect ttings, the installer must use an heavy
duty, AGA design-certi ed commercial exible connector of at least ½”(1.3cm)ID NPT(with suitable strain relieves)
in compliance with ANSI Z21.41 and Z21.69 standards.
2. In Massachusetts: The unit must be installed with a 36” (3-foot) long exible gas connector.
3. In Canada: CAN 1-6.10-88 metal connectors for gas appliances and CAN 1-6.9M79 quick disconnect device for
use with gas fuel.
CAUTION: Leak testing of the appliance shall be conducted according to the manufacturer’s instructions. Before placing the
oven into operation, always check for leaks with a soapy water solution of other acceptable method. DO NOT USE AN OPEN
FLAME TO CHECK FOR LEAKS!
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ilve UM90 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ilve UM90 in the language / languages: English as an attachment in your email.

The manual is 2,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info