749806
39
Zoom out
Zoom in
Previous page
1/48
Next page
The manufacturer declines any
liability if these safety measures
are not observed.
This hob is designed to be connected to a
220-240 V 50-60 Hz AC electrical supply.
Before switching on, make sure the
electricity supply voltage is the same as that
indicated on the hob rating plate. The
rating plate is located below the surface of
the casing.
The hob is supplied with a 3 core flexible
supply cord.
Upon completion there must be no cut, or
stray strands of wire present and the cord
clamp must be secure over the outer sheath.
Replacement of the connection cable
Warning! To replace the
connection cable, the technician
must have a specific equipment.
In this case, only cable type H03V2V2-F
T90 must be used. The cable section must
be suitable to the voltage and the working
temperature. The yellow and green earth
wire
2
must be approximately 2 cm longer
than the brown or black phase wire
1
.
1
2
Gas connection
Warning! Refer to Safety
chapters.
Caution! Information for
authorised installer only.
Connection to main pipe
Warning! This appliance is not
connected to a combustion
products evacuation device.
Before you proceed with the
installation, make sure that the
local distribution conditions,
nature of the gas and gas
pressure, and the adjustment of
the appliance are compatible.
The installation must be compliant with the
current local regulations. Complying with
the local regulations, the connection of the
cooktop to the gas pipe network or gas
cylinder must be made by means of a rigid
copper or steel pipe with fittings, or by
means of a continuous surface stainless
steel hose.
If there is a problem with the
pipe, do not repair it yourself.
Contact the local After Sales
Service Provider. Refer to the
Service chapter.
The connection must be installed correctly
and fixed into the hob connection pipe.
Otherwise, gas may leak from the
connection pipe.
ENGLISH 39
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ikea Matmassig 603.768.49 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ikea Matmassig 603.768.49 in the language / languages: English, Dutch as an attachment in your email.

The manual is 0,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ikea Matmassig 603.768.49

Ikea Matmassig 603.768.49 User Manual - German - 48 pages

Ikea Matmassig 603.768.49 Installation Guide - All languages - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info