Operating, shipping, and storage conditions
Accessories
Use only accessories provided by the original manufacturer,
and check for any missing accessories.
1 IR Thermometer
1 Instruction manual
2 AAA batteries
1 Quick user guide
Standard icons
Electromagnetic Compatibility (EMC) Tables
(1) Operating conditions
Range of operating environments
Temperature: 59-104℉(15- 40)
Humidity: 15-85%RHnon-condensing
Atmospheric Pressure: 70kPa~106kPa
(2) Transportation / storage conditions
8
Main Unit: -4~131℉(-20~ 55℃)
Humidity: 15-95%RH, non-condensing
Atmospheric Pressure: 70kPa~106kPa
Guidance and manufacturer’s declaration -
electromagnetic emissions
The PT3 device is intended for use in the electromagnetic
environment specified below.The customer or the user of the
PT3 should assure that it is used in such an environment.
Emissions test
RF emissions
CISPR11
Compliance
Group 2 The PT3 device must emit
electromagnetic energy in
order to perform its intended
function. Nearby electronic
equipment maybe affected.
RF emissions
CISPR11
Harmonic
emissions
lEC61000-3-2
Voltage
fluctuations/
flickeremissions
lEC61000-3-3
Class B
Not applicable
Not applicable
The PT3 device is suitable for
use in all establishments
other than domestic and
those directly connected to
the public low-voltage
power supply network that
supplies buildings used for
domestic
purposes.
Guidance and manufacturer’s declaration —
electromagnetic immunity
The PT3 device is intended for use in the electromagnetic
environment specified below.The customer or the user of the
PT3 should assure that it is used in such an environment.
Immunity test IEC 60601 Test
level
±6kV contact
±8kV air
Compliance
level
±6kV contact
±8kV air
Attention: Follow instructions for use!
(The sign background color: blue. The sign
graphical symbol: white.)
Authorized representative in the European
Community
Floors should be
wood , concrete or
ceramic tile.
If floors are
covered with
synthetic material,
the relative
humidity should
be at least 30%.
Electromagnetic
environment -
guidance
The batteries and electronic instruments must
be disposed of in accordance
with the locally applicable regulation, not with
domestic waste.
Electromagnetic environment
-guidance
Calibration
Storage
1) Do not put the thermometer under direct
sunlight, high temperature, or moist
environments. Do not allow it to come into
contact with fire or harsh vibrations.
2) Take out the battery if the device is not used for
a long period of time.
The thermometer is initially calibrated at the time of
manufacture. If this thermometer is used according to the
use instruction, periodic re-adjustment is not required. If any
time your question the accuracy of measurement, please
contact distributor or manufacturer, the contact information
is on the last page.
0120
Serial number
IP code of the device: this device’s grade of
against ingress of solid foreign objects -- ≥
12.5mm diameter (and the against access to
hazardous parts with finger); the grade of
waterproof is dripping (15° tilted).
Electrostatic
discharge(ESD)
lEC61000-4-2
Guidance and - manufacturer’s declaration.
Electromagnetic immunity
The PT3 device is intended for use in the electromagnetic
environment specified below. The customer or the user of the
PT3 should assure that it is used in such an environment.
9
Complies with MDD 93/42/eec Requirements
Manufacturer information
Symbol for "WARNING"
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for iHealth PT3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of iHealth PT3 in the language / languages: English, French, Spanish as an attachment in your email.

The manual is 0,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info