731661
3
Zoom out
Zoom in
Previous page
1/20
Next page
2 3
LED screen instructions
Temperature
display area
Celsius
Fahrenheit
Low power
reminder
Device dimensions: 5.39 in x 1.34 in x 1.54 in
Screen dimensions: 1.01 in x 0.75 in
Product weight: 90 g
Product performance
1. Measurement position: Centre of the forehead surface
2. Measurement distance: ≤1.18in(3 cm)
3. Power source: DC 3V; 2 x 1.5V AAA batteries
4. Measurement range: 89.6-109.2(32-42.9)
5. Measurement precision: ±0.4 within 95-107.6,
and±0.5 for other temperature ranges.
6. Resolution: 0.1
7. Clinical reproducibility: Within ±0.5
8. Operating conditions:
Temperature: 59-104(15-40)
Humidity: 15-85%RH, non-condensing
Atmospheric Pressure: 70~106kPa
9. Operation mode:
Adjusted mode: forehead
Direct mode: surface mode
10. Expected service life: 2 years
11. Reference Body Site: Oral
12. Software version: V1.0
1. This product is a precision device. Return the product to its
original packaging for proper storage after use. To ensure
accurate measurements, avoid the device or probe
contacting any liquid or droplets. Avoid tiny particles (such
as dust or powder) falling into the probe.
2. Avoid dropping or subjecting the product to external
forces. Do not disassemble or re-assemble the product on
your own.
3. Do not directly touch the probe with your fingers or blow
on it. Measurements taken using a damaged or dirty IR
probe may be inaccurate.
4. Keep the product at a place inaccessible to children to
prevent children from swallowing the batteries or small
parts.
5. Do not throw the thermometer or batteries into fire to
prevent explosions.
6. Remove the batteries from the thermometer if the device
will not be used for more than one month.
7.If you are allergic to plastic/rubber, please don’t use this
device.
8.The materials (ABS, TPU, metal) of expect contact with
patient had passed the ISO 10993-5 and ISO 10993-10
standards test, no toxicity, allergy and irritation reaction.
They are in compliance with the MDD requirements.
Based on the current science and technology, other
potential allergic reactions are unknown.
(2) About the product
measurement accuracy. We recommend taking only up to
3 continuous readings within a short period.
10. Do not directly face the sun or an air outlet of an air
conditioning or radiator device during the measurement
as this will cause changes to the forehead temperature.
Measurements should be taken in a stable environment
where possible.
11. Do not measure body temperature in an environment
with strong EM interference (examples include places
close to a working microwave, induction cooker, or
cellphone in-use) as EM interference may cause errors in
the reading or even device failure.
12. This product should be considered a personal device.
Clean and sanitize the product properly to prevent cross
contamination.
13. To clean a dirty thermometer probe, gently swipe the
probe using a cotton swab dipped in 75% alcohol. Let the
cleaned thermometer sit for at least 15 minutes before
taking more measurements.
14. This infrared thermometer meets requirements
established in ASTM Standard (E1965-98) Except of clause
5.2.2. It displays subject’s temperature over a range of 89.6
~109.2. Full responsibility for the conformance of this
product to the standard is assumed by (manufacturer:
Famidoc Technology Co., Ltd. Add:
No. 212 Yilong Road, Hexi Industrial Zone, Jinxia, Changan
Town, Dongguan 523853, Guangdong Province, China.)
LED display
area
Thermometer
probe
Distance
probe
Battery cover
Measurement
button
Overall Description
ASTM laboratory accuracy requirements in the display range
of 98°F to 102°F(37) for IR thermometers is ±0.4°F(±0.2),
whereas for mercury in-glass and electronic thermometers,
the requirement per ASTM Standards E667-86 and E1112-86
is ±0.2°F(±0.1).
The thermometer is mainly comprised of a plastic casing, IR
temperature sensor, MCU, vibration motor, LED display screen
and batteries.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for iHealth PT3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of iHealth PT3 in the language / languages: English, French, Spanish as an attachment in your email.

The manual is 0,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info