615934
61
Zoom out
Zoom in
Previous page
1/74
Next page
1 SignalTEK CT 156840.02
SignalTEK CT
User Guide
Guide d’utilisation
Bedienungsanleitung
Guida utente
Manual de usuario
Guia do Usuário
户指
156840.02 (06/2015)
IDEAL INDUSTRIES LTD.
Stokenchurch House
Oxford Road
Stokenchurch
High Wycombe
Buckinghamshire
HP14 3SX UK
www.idealnetworks.net
156840.02 SignalTEK CT 2
English
Français
Deutsch
Italiano
Español
Português
中文
© IDEAL INDUSTRIES LTD. 2015
The information contained in this document is the property of IDEAL INDUSTRIES Ltd. and is supplied
without liability for errors and omissions. No part of this document may be reproduced or used except as
authorized by contract or other written permission from IDEAL INDUSTRIES Ltd. The copyright and all
restrictions on reproduction and use apply to all media in which this information may be placed. IDEAL
INDUSTRIES Ltd. pursues a policy of continual product improvement and reserves the right to alter without
notice the specification, design, price or conditions of supply of any product or service. All rights reserved.
iPhone® and iTunes® are trademarks of Apple Inc., registered in the U.S. and other countries. Google
Play™ and Android™ are trademarks of Google, Inc.
Die Informationen in diesem Dokument sind das Eigentum von IDEAL INDUSTRIES Ltd. und werden ohne
Gewährleistung der Vollständigkeit oder Korrektheit gegeben. Dieses Dokument darf nur soweit vertraglich
oder anderweitig schriftlich von IDEAL INDUSTRIES Ltd. Zugesichert ganz oder teilweise vervielfältigt
werden. Das Urheberrecht und alle Einschränkungen zur Vervielfältigung und Nutzung gelten für alle
Datenträger, auf denen diese Informationen gespeichert werden können. IDEAL INDUSTRIES Ltd. bemüht
sich um ständige Produktverbesserungen und behält sich das Recht vor, die Spezifikation, das Design, den
Preis oder die Lieferbedingungen jeglicher Produkte oder Dienste ohne Vorankündigung zu ändern. Alle
Rechte vorbehalten.
iPhone® und iTunes® sind in den USA und anderen Ländern eingetragene Marken von Apple Inc. Google
Play™ und Android™ sind Marken von Google, Inc.
Le informazioni contenute nel presente documento sono di proprietà di IDEAL INDUSTRIES Ltd. e sono
fornite senza alcuna responsabilità relativa a errori e omissioni. Sono vietati la riproduzione o l'uso di tutto il
documento o parte di esso, salvo se autorizzati da contratto o permesso scritto di IDEAL INDUSTRIES Ltd.
Il copyright e tutte le limitazioni sulla riproduzione e l'uso si applicano a tutti i supporti nei quali le presenti
informazioni possono essere contenute. IDEAL INDUSTRIES Ltd. segue una politica volta al
miglioramento continuo dei prodotti e si riserva il diritto di modificare senza preavviso le specifiche, il
disegno, il prezzo o le condizioni di fornitura di qualsivoglia prodotto o servizio. Tutti i diritti riservati.
iPhone® e iTunes® sono marchi di Apple Inc., registrati negli Stati Uniti e in altri Paesi. Google Play™ e
Android™ sono marchi di Google, Inc.
La información que figura en este documento es propiedad de IDEAL INDUSTRIES Ltd., quien no asume
responsabilidad alguna sobre posibles errores u omisiones que puedan existir en este documento. Queda
prohibida la reproducción parcial o total de este documento, así como darle un uso distinto al autorizado
mediante contrato o autorización escrita por parte de IDEAL IDUSTRIES Ltd., independientemente del
formato y soporte de los contenidos. IDEAL INDUSTRIES Ltd. sigue una política de mejora continua del
producto y nos reservamos el derecho de modificar sin previo aviso las especificaciones, diseño, precio o
condiciones de suministro de cualquier producto o servicio. Todos los derechos reservados.
iPhone® e iTunes® son marcas comerciales de Apple Inc., registradas en los EE. UU. y en otros países.
Google Play™ y Android™ son marcas comerciales de Google, Inc.
As informações contidas neste documento são de propriedade de IDEAL INDUSTRIES Ltd. e são
fornecidas sem responsabilidade sobre erros e omissões. Nenhuma porção deste documento pode ser
reproduzida ou usada exceto quando autorizada mediante contrato ou outra permissão por escrito da
IDEAL INDUSTRIES Ltd. Os direitos de cópia e restrições de reprodução e uso são aplicáveis a todas as
mídias nas quais estas informações possam ser colocadas. A IDEAL INDUSTRIES Ltd. segue uma política
de melhora contínua do produto e se reserva ao direito de alterar sem aviso prévio as especificações,
design, preço ou condições de fornecimento de qualquer produto ou serviço. Todos os Direitos
Reservados.
iPhone® e iTunes® são marcas registradas da Apple Inc. nos EUA e em outros países. Google Play™ e
Android™ são marcas registradas da Google, Inc.
本文档所包含的信息是美国理想工业公司 (IDEAL INDUSTRIES Ltd.) 财产,对于本文档中出现的错误或
遗漏,提供方概不负责。除非得到美国理想工业公司的合同授权或其他书面许可,否则,本文档的任何
分均不得复制或使用。版权和对复制和使用的所有限制都适用于本信息发布的一切媒介。美国理想工业公
司奉行持续改进产品的政策,并保留在不事先通知的情况下变更任何产品或服务的规格、设计、价格或
货条件的权利。保留所有权利。
iPhone® iTunes® 为苹果公司在美国及其他国家/地区的注册商标。Google Play™ Android™ 为谷歌
司的商标。
Les informations dans ce document sont la propriété de IDEAL INDUSTRIES Ltd. et elles sont
fournies sans responsabilité pour les erreurs et les omissions. Aucune partie de ce document ne doit
être reproduite ou utilisée, sauf en cas d’autorisation par contrat ou en cas d’autre autorisation écrite
donnée par IDEAL INDUSTRIES Ltd. Le copyright et toutes les limitations concernant la reproduction
et l’utilisation s’appliquent à tous les supports sur lesquels cette information peut être placée. IDEAL
INDUSTRIES Ltd. améliore continuellement ses produits et se réserve le droit de modifier sans
préavis la spécification, la conception, le prix ou les conditions de fourniture d’un produit ou d’un
service. Tous droits réservés.
iPhone® et iTunes® sont des marques déposées d'apple inc., enregistrées aux usa et dans d'autres
pays. Google play™ et android™ sont des marques déposées de google, inc.
3 SignalTEK CT 156840.02
INTRODUCTION
Comprehensive testing of installed data cables is essential in order to:
Prove that the cables are capable of carrying Ethernet traffic, error-free in accordance with the
Ethernet standard
Prove that they are correctly wired
Minimise call-backs
Two tests are essential to achieving this quality standard:
A data test which sends Ethernet traffic over the cable and checks that its performance
complies with the IEEE 802.3ab standard
A wiremap test which checks that the wiring is free from faults
SignalTEK CT is a Data Cable Transmission Tester that allows you to:
Perform both of the required tests automatically, measure the cable length, and save the
results, all from a single button press
Review the results, identify any faults found and re-test after repairs if necessary
Create and output a report as documented proof that the cables tested are fit for purpose, and
as a record of the length of cable installed
TEST PRINCIPLE
A typical procedure for testing and documenting a number of cables in a job is:
1. Enter into the tester the details of the engineer performing the tests, and your company logo if
required, for inclusion in the final report
2. Enter into the tester the details of the job, including client details as appropriate and cable
Category if required, for inclusion in the final report
3. For each cable to be tested:
a. Connect the SignalTEK CT Test Unit to one end of the cable
b. Connect the SignalTEK CT Remote Unit to the other end of the cable
c. Press the yellow Autotest button on either Unit
d. Allow the two tests to be completed (approx. 20secs total)
e. Move on to the next cable and repeat steps (a) to (d)
4. When all of the cables have been tested:
a. (Optional) Review the results, repair and re-test any faulty cables
b. Plug a USB memory key into the Test Unit
c. Save a full or summary report for delivery to the client
SAFETY INFORMATION
When using SignalTEK CT, always take basic safety precautions to reduce the risk of fire, electric
shock and injury to persons. These include the following:
When connecting to the line, special care must be taken as high voltages may be present
on the line and there may be a danger of electrocution.
Avoid using the tester during an electrical storm - there is a remote risk of electric shock
by lightning.
Use only the mains electricity adaptor supplied with your SignalTEK CT.
DO NOT CONNECT ANY TELECOMMUNICATIONS NETWORK
TO ANY OF THE TESTER’S PORTS
156840.02 SignalTEK CT 4
En
Test Unit
Remote Unit
USB socket
Used for uploading results and for
downloading user logo and software
updates
Display
Shows settings and results
Function buttons
Press to activate the function shown
in the screen area above the button
Escape button
Press to go back to the previous
screen without saving changes
ENTER button
Press to select the currently
highlighted screen function, or to
confirm changes
Saved LED
Indicates that the result has been
saved in the Test Unit
Charging Indicator LED:
Charging
Charging complete
(Flashing) Not charging
Battery status LED:
(Power ON) Battery level is
sufficient for use
(Power ON) Battery charge
level is low but still operational
Power OFF
Power button
Press to switch the Remote Unit
ON/OFF
Autotest button
Press to start the Autotest
from the Remote Unit end of
the cable
Link LED
Indicates that the Remote Unit is
connected to the Test Unit
Pass/Fail LED
Flashes to indicate that a test is in progress.
When the test is complete,
indicates the result:
Test passed
Test failed
DC Input
Used to connect the
power supply / charger
(12vDC 2.5A)
Rechargeable battery module
(Non-rechargeable backup battery
packs are also available)
Autotest button
Press to start the Autotest
from the Test Unit end of the
cable
Power button
Press to switch the Test Unit
ON/OFF
Cable socket
Used to connect
the units to the
cable to be tested
Ethernet LED
Indicates that
Ethernet is
connected
Activity LED
Indicates Ethernet
data activity
Cursor buttons
Press to change which screen
function or item is highlighted
WiFi Adaptor
Connects to smartphone app
5 SignalTEK CT 156840.02
HOME SCREEN
The HOME screen is displayed following start-up. (To return to the HOME screen from any other
screen, press Escape repeatedly until the HOME screen appears.)
When the Remote Unit Icon is displayed, indicating that the two units are connected together via the
cable to be tested, press Autotest at either end to start the tests.
Memory Status
Shows the number of
results stored / total
capacity
Battery Status:
Battery full
Battery
2
/
3
full
Battery
1
/
3
full
Battery empty
Mains / on charge
Current time
Data Test Icon
Indicates progress of the
Data Test. Highlight the
icon using the cursor
buttons and press Enter to
view the details of the Data
Test.
Cable length
(Indicated
after the tests
are complete)
Notifications Area
Shows the current activity or
status of the tester
Test Unit Icon
Remote Unit Icon
Indicates that the
Remote Unit is
connected to the Test
Unit
Wiremap Test Icon
Indicates progress of the
Wiremap Test. Highlight the
icon using the cursor
buttons and press Enter to
view the details of the
Wiremap Test.
Test Status:
Ready to test
Test in progress
Test Passed
Test Failed
Auto Save Selection
Highlight the icon using the
cursor buttons and press Enter
to select how results should be
saved
JOBS
Press F1 (JOBS) to
access the JOBS menu.
SETUP
Press F3 (SETUP) to
access the SETUP
menu.
Result Name
Shows the name of
the last saved result
Job Selection
Shows the currently
selected Job. Highlight the
icon using the cursor
buttons and press Enter to
select which Job to save
results to.
STOP / SAVE / NAME
Press F2 (STOP) to
interrupt the test, or
(SAVE) to save the result
manually, or (NAME) to
edit the name format of the
subsequent test results
156840.02 SignalTEK CT 6
En
SETUP
Select SYSTEM to access the system setup:
Enter details of the test engineer and company for inclusion in the reports
Set the menu language
Set preferences for auto off, backlight, length units, date and time format
Set the date and time for inclusion in the reports
Update the software. All settings and results will be lost. Save data to USB first.
View details about the system
Reset to factory defaults. All settings and results will be lost. Save data to USB first.
Adjust the settings to be used in the tests:
Cable Type
Select number of pairs and color scheme:
If 2-Pair is selected, the Data Test will run at 100Mb/s.
If 4-Pair is selected, the Data Test will run at 1Gb/s
Shield Type
Select how the shield will affect the Wiremap Test:
UTP Wiremap Test will only pass if the cable shield is not connected
STP Wiremap Test will only pass if the cable shield is connected
UTP/STP Shield will not affect the result of the Wiremap test
Nominal Velocity of Propagation (NVP)
Accurate length measurement relies on correct setting of the Nominal Velocity
of Propagation (NVP) for the cable to be tested.
Shows an illustration of the cable based on the selected cable type
SignalTEK CT can be used together with a compatible tone probe (available from
IDEAL) to identify and trace cables. SignalTEK CT can generate various types of tone on
various combinations of pins. Choice of tone type and pin connection is best determined by
experiment, to achieve the best results with a particular probe type and in a particular cable
situation.
Select the required report style:
Format
o PDF for graphical reports that can be viewed or printed using a PDF viewer
o CSV for editable reports that can be opened in a spreadsheet
Size
o FULL to include all details (larger file, takes longer to upload)
o SUMMARY (smaller file, takes less time to upload)
Include length measurement in the reports if required
7 SignalTEK CT 156840.02
DATA TEST SCREEN
If more detail is required about the Data Test, the Data screen can be displayed by highlighting the
Data Test icon on the HOME screen and pressing Enter.
Summary
Shows the status of the test
Duration
Shows the duration of the test. In order
to comply with the Ethernet standard
at 1Gb/s, the data test must be run for
10 seconds
Test Status:
Ready to test
Test in progress
Test Passed
Test Failed
Notifications Area
Shows details of the test
status
Frames Sent
Shows the number of Ethernet
frames sent over the cable. In
order for the cable to comply
with the Ethernet standard at
1Gb/s, 823,452 frames
(containing 10
10
bits) must be
sent and received error free
Frames Received
Shows the number of Ethernet
frames received error free
Frame Errors
Shows the number of errored
Ethernet frames received. One or
more errors will cause the cable to
fail the Ethernet standard
Press F2( FAULT) to display possible fault
causes
Possible causes of data test failures include:
Excessive cable length. The maximum length allowed by the Ethernet standard for 1Gb/s is
100 metres. Cables longer than this may still operate error free, but may be unreliable. Even
cables shorter than this may produce data errors and fail the data test if they have other
faults. If the Data Test fails, check the length of the cable ( shown in the HOME screen and in
the Wiremap result). If the cable exceeds 100 metres in length, it is recommended to replace
it with a shorter one.
Bad twisting. For optimum performance it is important that the twisting of the individual pairs
is carried right up to the termination, to avoid crosstalk which can affect data performance.
Bad twisting does not show up as a wiremap fault. If the data test fails, it is recommended to
inspect the terminations and re-terminate if the twisting is sub-standard.
Poor cable quality. Some brands of cable can give inferior data performance and cause
data errors, especially on longer lengths. If the data test fails, but the wiremap test passes,
and the length is approaching 100 metres, it is recommended to check the cable quality
Split pairs. Split pairs can cause data errors or complete failure of the cable to carry Ethernet
traffic. Cables that are a composite of a long length with no split pairs, connected to a shorter
length with split pairs, may not show up as a wiremap fault but can cause data errors and fail
the data test.
Data errors can occur even if the wiremap shows that the cable is correctly terminated. That is why it
is important to perform both the data test and the wiremap test to prove that the cable meets all of
the required quality standards.
156840.02 SignalTEK CT 8
En
WIREMAP TEST SCREEN
If more detail is required about the Wiremap Test, the Wiremap screen can be displayed by
highlighting the Wiremap Test icon on the HOME screen and pressing Enter.
Summary
Shows the status or result of the test. In this example, pins 1 and 2 are reversed, resulting in a
miswire fault. Ethernet is tolerant of such a fault, so the Data Test will pass in this case. That is why
it is important to perform both the data test and the wiremap test to prove that the cable meets all
of the required quality standards.
Test Status:
Ready to test
Test in progress
Test Passed
Test Failed
Shows the length of each pair (some
pairs may be longer than the overall
cable due to the cable construction)
Cable Type
Shows cable type selected in
SETUP
Remote Unit pin numbers
Test Unit pin numbers
Shows the overall cable length
Press F3 (SETUP) to adjust the
test settings
Press F1 (RUN) to run the
Wiremap test for
troubleshooting (result can not
be saved)
Press F2 (FAULT) to view the fault details
A split pair is a wiring error in which each pin is connected to the correct pin at the other end of the cable, but
the pairs of pins are connected using wires from different twisted pairs. Split pairs can cause crosstalk and
data failures, but are not reported as faults by simple wiremappers. The advanced wiremapper in SignalTEK
CT can detect split pairs that some other wiremappers can not detect. Split pairs can start with a simple wiring
error. In the example below, pins 3 and 4 are reversed at one end of the cable:
5
4
3
6
5
4
3
6
5
4
3
6
5
4
3
6
5
4
3
6
5
4
3
6
If the error is repaired at end of the cable where the fault is located, the fault is removed:
If the error is repaired at the wrong end of the cable, the end-to-end continuity is corrected,
but a split pair is formed:
This cable may cause Ethernet data errors, and if so it will fail the SignalTEK CT Data Test.
9 SignalTEK CT 156840.02
JOBS
Test results can be organised into folders called Jobs. A maximum of 5000 results can be stored, each
consisting of a Data Test result and a Wiremap Test result, divided into a maximum of 50 Jobs. Jobs can
be uploaded from the tester to a USB memory key and it is recommended to do this regularly to provide a
backup against loss of data.
Following a factory reset a default job “MyJob” is created. To change the name of the Job, press F1 (JOBS)
on the HOME screen then F1 (EDIT). The Job name and up to 8 Information fields can be edited by
selecting the required field with the cursor keys and pressing ENTER. Note that spaces are not allowed in
Job names, and any space that is entered will automatically be converted to an underscore character.
When all of the required details are complete, press F2 (APPLY). The details will be included when the Job
is uploaded to USB.
To create another Job, press F1 (JOBS) on the HOME screen then F2 (OPTIONS). Select NEW and press
ENTER. Fill in the new Job name. The Information fields are automatically copied from the last Job and can
be changed if required.
Select the Job that is to be used as the current Job by highlighting the Job Selection box on the HOME
screen using the cursor keys, pressing ENTER and selecting the required Job.
By selecting the Auto Save box on the HOME screen, the results can be set to save automatically,
manually, or only if the test is passed.
The first time a test is run with a new or empty Job, the result can be saved manually, even if Auto Save is
switched on. This allows the format of the result name to be adjusted and used for all subsequent results.
To adjust the result name, move the highlight to the Result field. The up/down cursor keys can then be
used to increase/decrease the result number or any other numerical part of the result name. Alternatively,
press ENTER to edit the result name. Subsequent tests will use the same result name format, but will
increment the result number, when the result is saved. For example, if the first result name is set to
“Cable0123”, the next result will automatically be saved to “Cable0124” and so on.
To view saved results, press F1 (JOBS) on the HOME screen. The Job list is displayed. Use the cursor
keys to scroll up/down the list to the required Job, then ENTER to display the list of results in the selected
Job. Use the cursor keys to scroll up/down the list to the required result, then ENTER to display the
Wiremap and Data Test information for the currently selected result. Press F1 (RENAME) to edit the name
of the currently selected result. Press F2 (DELETE) to delete the currently selected result. Press F3 to
show ALL results, only PASS results or only FAIL results
If a cable needs to be re-tested, for example if it previously failed but has now been repaired, select the
result in the result list using the cursor keys. Press ENTER. then F1 (RETEST). This returns to the HOME
screen, runs a new test on the cable and automatically saves the result using the selected name,
overwriting the old result.
When a Job is complete, it can be uploaded from the tester to a USB memory key. Select the required Job
in the Job list then press F3 (TO USB). Select the required report style then press F1 (CONFIRM). Insert a
USB memory key and press ENTER. This does not remove the Job from the tester the Job is only copied
to the USB key and more results can still be added to it later if required. Alternatively, all of the Jobs can be
uploaded at once by pressing F2 (OPTIONS) in the Job screen then selecting ALL TO USB in the Options
screen. This screen also allows all stored Jobs to be deleted.
156840.02 SignalTEK CT 26
De
SETUP
SYSTEM wählen, um das System-Setup aufzurufen:
Details zum Prüftechniker und der Firma zur Aufnahme in den Bericht eingeben
Menüsprache wählen
Einstellungen für Auto Aus, Displaybeleuchtung, Längeneinheiten,
Datums- und Uhrzeitformat eingeben
Datum und Uhrzeit für die Berichte eingeben
Software aktualisieren. Alle Einstellungen und Ergebnisse werden gelöscht.
Daten zunächst auf USB-Stick speichern.
Angaben zum System
Auf Werkseinstellungen zurücksetzen. Alle Einstellungen und Ergebnisse
werden gelöscht. Daten zunächst auf USB-Stick speichern.
Einstellungen für die Prüfungen ändern:
Kabeltyp
Anzahl der Kabelpaare und Farben wählen:
Wenn 2-Paar ausgewählt wird, läuft der Datentest mit 100 Mb/s.
Wenn 4-Paar ausgewählt wird, läuft der Datentest mit 1 Gb/s.
NVP (Ausbreitungsnenngeschwindigkeit)
Die präzise Längenmessung ist abhängig von der korrekten Einstellung der
Ausbreitungsnenngeschwindigkeit (NVP) des zu prüfenden Kabels.
Zeigt das Kabel basierend auf dem ausgewählten Kabeltyp.
SignalTEK CT kann in Verbindung mit einer kompatiblen Tonsonde (erhältlich von IDEAL) zur Identifizierung und
Verfolgung von Kabeln eingesetzt werden. SignalTEK CT kann verschiedene Tontypen auf verschiedenen
Stiftkombinationen erzeugen. Die Wahl des Tontyps und der Stiftverbindung wird am besten durch Ausprobieren ermittelt,
um die besten Ergebnisse für einene spezifischen Sondentyp und in einer bestimmten Kabelsituation zu erzielen.
Den erforderlichen Berichtsstil wählen:
Format
o PDF für Grafiken, die mit einem PDF-Viewer betrachtet oder gedruckt werden
können
o CSV für Berichte, die in einer Tabellenkalkulation geöffnet und bearbeitet werden
können
Größe
o VOLL, mit allen Details (größere Datei, Upload dauert länger)
o ZUSAMMENFASS. (kleinere Datei, Upload ist schneller)
Bei Bedarf wird auch die Längenmessung in die Berichte aufgenommen
Schirmtyp
Auswirkung des Schirms auf den Verdrahtungstest auswählen:
UTP der Verdrahtungstest ist nur dann erfolgreich, wenn kein Kabelschirm
angeschlossen ist
STP der Verdrahtungstest ist nur dann erfolgreich, wenn der Kabelschirm
angeschlossen ist
UTP/STP der Schirm hat keinen Einfluss auf das Ergebnis des Verdrahtungstests
156840.02 SignalTEK CT 38
Es
SCHERMATA TEST MAPPATURA
Se si necessita di maggiori dettagli sul test di mappatura, è possibile visualizzare la schermata Mappatura
evidenziando l'icona Test mappatura nella schermata principale e premendo Enter.
Sommario
Mostra lo stato o il risultato del test. In questo esempio i pin 1 e 2 sono invertiti, con un conseguente errore nel
cablaggio. Lo standard Ethernet non giudica grave questo difetto, quindi in tal caso il test dati viene superato.
Questo è il motivo per cui è importante eseguire sia il test dati che il test di mappatura al fine di verificare che il
cavo soddisfi tutti gli standard di qualità necessari.
Stato test:
Pronto per il test
Test in corso
Test passato
Test fallito
Mostra la lunghezza di ogni coppia (alcune
coppie possono essere più lunghe dell'intero
cavo a causa della struttura del cavo stesso).
Tipo Cavo
Mostra i tipi di cavi selezionati
in SETUP.
Numeri pin unità remota
Numeri pin unità di test
Premere F3 (SETUP) per configurare
le impostazioni di test.
Premere F1 (INIZIA) per
eseguire il test di mappatura
per la risoluzione dei problemi (i
risultati non potranno essere
salvati.)
Premere F2 (ERRATO) per visualizzare i dettagli
del guasto.
Una coppia splittata è un errore di cablaggio secondo cui ogni pin è collegato al pin corrispondente all'estremità
opposta del cavo, ma le coppie di pin sono collegate tramite fili di doppini diversi. Le coppie splittate possono causare
diafonia ed errori di dati, ma non sono rilevate come guasti da semplici dispositivi di mappatura. La funzione di
mappatura avanzata di SignalTEK CT è in grado di rilevare coppie splittate che altri dispositivi non riescono a
individuare. Le coppie splittate possono iniziare con un semplice errore di cablaggio. Nell'esempio seguente, i pin 3 e 4
sono invertiti a un'estremità del cavo:
5
4
3
6
5
4
3
6
5
4
3
6
5
4
3
6
5
4
3
6
5
4
3
6
Se l'errore viene riparato all'estremità del cavo dove è localizzato il guasto, quest'ultimo viene eliminato:
Se l'errore viene riparato all'estremità del cavo errata, la continuità end-to-end viene corretta, ma
si forma una coppia splittata:
Mostra la lunghezza
totale del cavo.
Questo cavo potrebbe provocare errori nei dati Ethernet e in tal caso non supera il test dati
SignalTEK CT.
156840.02 SignalTEK CT 60
Pt
RELATÓRIOS
Os relatórios são muito importantes, pois são um documento que comprova que os cabos testados estão
adequados para utilização, e são um registro do comprimento do cabo instalado. Para selecionar o estilo de
relatório desejado, pressione F3(CONFIG) na tela INÍCIO, e selecione RESULTADO.
Para incluir seu próprio logotipo nos relatórios em PDF, na tela INÍCIO, selecione F3
(CONFIG) / SISTEMA / DONO / F1 (LOGO). Insira um dispositivo USB contendo uma
imagem com o nome logo.png, com tamanho máximo de
250 x 160 pixels.
Para incluir seus detalhes nos relatórios, na tela
INÍCIO, selecione F3 (CONFIG) / SISTEMA / DONO.
Para incluir os detalhes do Trabalho nos relatórios, na
tela INÍCIO, selecione F1 (TRABALHOS) / F1 (EDITAR)
ou F2 (OPÇÕES) / NOVO.
Há 3 relatórios disponíveis
O relatório de Resumo lista um resumo de todos os testes em um serviço.
O relatório Sumário lista todos os detalhes de todos os testes.
O relatório Completo combina o relatório de Resumo e o Sumário em um documento
O Test0001 é um cabo 4-Pair 568B UTP de 2
metros de comprimento Ele reprovou o Wiremap
porque o pino 7 está faltando e reprovou os testes
de Dados por não suportar 1Gbit/s. No entanto,
suporta 10Mb/s e 100Mb/s.
O Test0002 é um cabo 4-Pair de 2 metros de
comprimento Passou nos testes de Wiremap e
Dados e suporta 10Mb/s, 100Mb/s and 1Gbit/s.
O Test0003 é um cabo 4-Pair 568A UTP de 2
metros de comprimento com os pinos 1 e 2
invertidos. Foi reprovado no teste de Wiremap,
mas passou no teste de Dados. Como a
reprovação do wiremap não é crítica, ele suporta
10Mb/s, 100Mb/s e 1Gb/s.
O Test0004 é um cabo 4-Pair 568B UTP de 2
metros de comprimento. Passou no teste de
Wiremap, mas reprovou no teste de Dados
porque foram detectados erros de Ethernet. Não
suporta 1Gb/s. Pode suportar 10Mb/s ou
100Mb/s, mas sem garantia.
O Test0005 é um cabo 2-Pair 568A UTP de 2
metros de comprimento. Passou nos testes de
Wiremap e Dados. Suporta 10Mb/s e 100Mb/s
61


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ideal Networks SignalTEK CT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ideal Networks SignalTEK CT in the language / languages: English, German, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 2,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info