615950
17
Zoom out
Zoom in
Previous page
1/34
Next page
NaviTEK NT 151844 Iss 2
User Guide Page 17
o Length - Number of bytes in the Ping packet
TRoute Setup
o TRoute - Include or omit the Trace Route test from the NET TEST
o Max Hops - The number of hops that can be detected before the test
fails to reach the destination target
o Timeout - the timeout before the test fails to reach the destination
target
o Name Lookup - When ticked, the name of each hop is included in the
test result. Note that selecting this option causes the test time to be
longer
IPv4 Netscan setup
o Netscan - Disable Netscan from inclusion in the NET TEST or select
Local or Custom network
o IP Addr - Set Custom network sub-net
o Scan range - Select a small scan range (Class C) for fast test time or
a larger scan range (Class B) for a wider search
o Subnet Mask - Select the subnet required
Set the details of the Power over Ethernet test:
Type
o PoE - Applies a load to draw current up to the maximum allowed for
PoE
o PoE+ - Applies a load to draw current up to the maximum allowed
for PoE+
o None - PoE test disabled
Min PoE power (W)
o Enter the minimum power in watts for the PoE test to pass
Min PoE+ power (W)
o Enter the minimum power in watts for the PoE+ test to pass
User Set up a list of targets to be used in the NET TEST, using IPv4 or IPv6 addresses
or URLs
Select RJ45 to set the parameters for the RJ45 copper port including Auto
Negotiation, Speed, Mode, Min Rx frame size, MDI and MAC address.
Select VLAN to set the VLAN ID and Priority of the tester if required
Select OPTICAL to view information about the SFP fitted. The SFP types that follow
are supported. The use of other SFP types is possible but correct operation is not
guaranteed.
Type
Manufac
turer
Part No
Speed
Fiber
type
Waveleng
th
Connector
Type
SX Avago AFBR-5705PZ 1Gb/s Multimode 850nm LC Duplex
SX Apac LM28-C3S-TI-N-DD 1Gb/s Multimode 850nm LC Duplex
LX Avago AFCT-5705PZ 1Gb/s Singlemode 1310nm LC Duplex
LX Apac LS38-C3S-TC-N-DD 1Gb/s Singlemode 1310nm LC Duplex
ZX Apac LS48-C3U-TC-N-DD 1Gb/s Singlemode 1550nm LC Duplex
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ideal Networks NaviTEK NT Pro at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ideal Networks NaviTEK NT Pro in the language / languages: English as an attachment in your email.

The manual is 6,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info