SERVICE MAN MENU
Service man menu
To open the SERVICE MAN menu.
Push [MENU]/[ ] several times to show the
SERVICE MAN menu.
Select the language
Menu screens can be displayed in 2 different
languages.
Selectable languages; ENGLISH, (CHINESE)
After opening the SERVICE MAN menu;
q Push [Ù] to show the present language.
w Push [
Ω≈
] to select desired language, then push
[Ú] to continue the setting.
e Push [MENU]/[ ] to exit the SERVICE MAN
menu.
D TIMING ADJ.
Corrects the distance.
D HDG ADJ.
Adjusts the electronic heading line adjustment.
D SPD ADJ.
Enter the pulse rate of the speed sensor.
D RANGE
1
8,
1
4,
1
2,
3
4, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 36,
48* : Choose the selectable screen range.
*MR-1000TII only
D SETUP MEMORY
The present setting value is displayed by pushing [
],
then select the desired item from RECALL and
SAVE using with [Ú].
q Push [
] to display RECALL and SAVE.
w Push [ÙÚ] to select RECALL or SAVE.
e Push [
].
•“SURE ? is displayed.
r Push [
] to perform.
t Push [
]
to cancel
.
When recall is performed without saving a setup, it
will become an initial value at the time of factory
shipments.
D Other readouts
OUTPUT VOLTAGE
: Shows the voltage level for the
scanner unit from the display unit.
HV (High voltage) : Shows the voltage level in the
high-voltage unit in the scanner
unit.
MONITOR : Shows the voltage level for
checking the receiver unit opera-
tion.
HEATER : Shows the heater current.
MG :Shows the current level for the
Magnetron.
TX TIME :Shows the total transmitted time.
SERVICE MAN
SPD ADJ.
HDG ADJ. 0.0
˚
HV
SETUP MEMORY RECALL
RANGE
24000 MONITOR
HEATER
5731.0H
TX TIME
30.0
OUTPUT
ENGLISH
VOLTAGE
SAVE MG
340
75
3.0
0.55
TIMING ADJ.
1/8 3/4 2 6
1/4 1 3 8
1/2 1.5 4 12
16
24
32
36
48
CAUTION: The SERVICE MAN MENU is available
for service purposes only. DO NOT change any set-
ting on the menu, otherwise the equipment may not
operate at its original performance.
MR-1000R2_T2.qxd 04.2.24 10:22 Page 32
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom MR1000TII at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom MR1000TII in the language / languages: English as an attachment in your email.

The manual is 2,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info