4
1
PANEL DESCRIPTION
[SKIP] (p. 25)
➥ Push momentarily to toggle the skip function ON
and OFF for any scan.
• Automatic skip activation is available with the [MEMO]
switch.
➥ Push for 1 sec. to set the memory channel as a skip
channel.
[AUTO] (p. 24)
➥ Push momentarily to start/stop auto write scan.
➥ Push for 1 sec. to select the written memories
condition for the auto write scan.
• Two conditions are available, clear auto-written mem-
ories before scan starts; and, keep auto written mem-
ories before scan start.
[VSC] (p. 26)
Push to toggle the voice scan control function ON
and OFF.
• The VSC function resumes the scan when a detected sig-
nal does not contain voice components.
•“VSC” appears while the voice scan control function is
activated.
[PRIO] (p. 25)
➥ Push momentarily to start/stop priority scan.
• Priority scan can be used in combination with other
scans.
➥ Push for 1 sec. to enter the priority channel pro-
gramming condition.
[DLY ] (p. 27)
➥ Push momentarily to select a scan resume condi-
tion.
➧ “OFF” is underscored: scan pauses on a signal until it
disappears, then resumes 3 sec. after that.
➧ “DLY” is underscored: scan resumes according to the
[DELAY/SPEED] control setting. When a signal dis-
appears, scan resumes 3 sec. later.
➧ “
∞
” is underscored: scan is cancelled when receiving
a signal.
➥ Push for 1 sec. to enter the delay time/scan speed
setting condition.
• The function of the [DELAY/SPEED] control can be se-
lected.
@8
KEYPAD
The keypad can be used for several functions as below:
• Keypad then [ENT] (then [MW])
— Direct frequency input.
• Keypad then [M-CH]
— Memory channel selection.
• [CE •
NAME] then keypad
— Alphanumeric input for memory, bank names, etc.
• Keypad then [TSY] or [TSZ]
— Arbitrary tuning step setting.
• Keypad then [MEMO] or [SEL]
— Specify memory bank then start memory scan or se-
lect memory scan.
• Keypad then [PROG] or [AUTO]
— Specify scan edge group, then start programmed
scan or auto write scan.