Resetting the CPU
Resetting CLEARS all programmed contents in
memory channels and returns programmed values
in set mode to their defaults.
When rst applying power or when the function seems
to be displaying erroneous information, reset the CPU
as follows:
q Make sure receiver power is OFF.
w While pushing [UP Y] and [Z DN], push [POWER]
to turn power ON.
The internal CPU is reset.
The receiver displays its initial VFO frequencies when
resetting is complete.
11
36
MAINTENANCE
Troubleshooting
The following chart is designed to help you correct
problems which are equipment malfunctions.
If you are not able to locate the cause of a problem or
solve it through the use of this chart, contact your near-
est Icom Dealer or Service Center.
[POWER] [ZDN] [UPY]
PROBLEM POSSIBLE CAUSE SOLUTION REF.
POWER
Power does not come on
when the [POWER] switch
is pushed.
DC power cable is improperly connected.
Fuse is blown.
Reconnect the DC power cable correctly.
Check for the cause, then replace the fuse with
a spare one.
(Fuses are installed in the DC power cable
and the internal MAIN unit.)
p. 37
RECEIVE
No sound comes from the
speaker.
Volume level is too low.
The squelch is closed.
Rotate [AF] clockwise to obtain a suitable
listening level.
Rotate [RF/SQL] to 12 oclock position to open
the squelch.
p. 2
p. 14
Sensitivity is low. The antenna is not connected properly.
The antenna for another band is selected.
The attenuator is activated.
Reconnect to the antenna connector.
Select an antenna suitable for the operating
frequency.
Push [ATT] to turn the function OFF.
p. 16
p. 16
Receive audio is distorted. The operating mode is not selected correctly.
PBT function is activated.
Noise blanker function is activated.
Preamp is activated.
The optional noise reduction is activated and
the [NR] level is set too high.
Select a suitable operating mode.
Set [TWIN PBT] to the center position.
Push [NB] to turn the function OFF.
Push [P.AMP] once or twice to turn the function
OFF.
Push [NR] to turn the function OFF.
p. 14
p. 15
p. 15
p. 16
p. 20
SCAN
Programmed scan does
not stop.
Squelch is open.
[RF/SQL] is assigned to RF gain control and
squelch is open.
Set [RF/SQL] to the threshold point.
Reset [RF/SQL] control assignment and set it to
the threshold point.
p. 14
pgs.
14, 30
Programmed scan does
not start.
The same frequencies have been programmed
in scan edge memory channels P1 and P2.
Program different frequencies in scan edge
memory channels P1 and P2.
p. 22
Memory scan does not
start.
2 or more memory channels have not been
programmed.
Program 2 or more memory channels.
p. 22
Select memory scan does
not start.
2 or more memory channels have not been
designated as select channels.
Designate 2 or more memory channels as select
channels for the scan.
p. 26
DISPLAY
F.AGC flashes in the
function display.
A scan or band scope function is activated via
an optional RS-R75 remote control software.
If these functions are not in use, push [AGC] to
deactivate the function.
The displayed frequency
does not change properly.
The dial lock function is activated.
The internal CPU has malfunctioned.
Push [LOCK] to deactivate the function.
Reset the CPU.
p. 13
See
below.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-R75 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-R75 in the language / languages: English as an attachment in your email.

The manual is 1,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info