32
9
SET MODE
• Recorder remote
This item sets the [REC REMOTE] jack function ON
or OFF.
• CI-V address
To distinguish equipment, each CI-V transceiver or re-
ceiver has its own Icom standard address in hexa-
decimal code. The IC-R75’s address is 5Ah.
When 2 or more IC-R75’s are connected to an op-
tional CT-17 CI-V LEVEL CONVERTER, rotate the tuning
dial to select a different address for each IC-R75 in
the range 01h to 7Fh.
• CI-V baud rate
This item sets the data transfer rate. “3” (300 bps),
“12” (1200 bps), “48” (4800 bps), “96” (9600 bps),
“HI” (19200 bps) and “At” (automatic) are available.
When “At” is selected, the baud rate is automatically
set according to the connected controller or remote
controller.
• CI-V with IC-735
When connecting the IC-R75 to the IC-735 for trans-
ceive operation, you must change the operating fre-
quency data length to 4 bytes.
• This item must be set to “ON” only when operating re-
ceiver with the IC-735.
• Speech language
When the optional UT-102 VOICE SYNTHESIZER UNIT is
installed, you can select between English and Japan-
ese as the language.
•“En” English announcement
•“JP” Japanese announcement
See p. 34 for unit installation.
• CI-V transceive
Transceive operation is possible with the IC-R75 con-
nected to other Icom HF transceivers or receivers.
When “on” is selected, changing the frequency, oper-
ating mode, etc. on the IC-R75 automatically changes
those of connected transceivers (or receivers) and
vice versa.