16
6
SCAN OPERATION
Full/band/programmed scan
q Select VFO mode with [V/M].
w Make sure the squelch is set to the threshold point.
Select automatic squelch (AUTO) or a level (19) where the
noise is muted. (p. 10)
e Select the desired scan range, if desired.
Select scan edges in set mode:
ALL for full scan, BANDfor band scan or 0P”–“19P
for programmed scan. (see the next page)
r Push [FUNC] + [Y] or [Z] momentarily to start the scan.
Decimal point ashes while scanning.
•“P SKIP”flashes when the frequency skip function is turned ON.
(p. 19)
•“0P”–“19P flash to indicate which pair of scan edges is being
scanned.
To change the scanning direction, rotate [DIAL].
If the pocket beep function is activated, the transceiver automat-
ically selects the tone squelch function when a scan starts.
t To stop the scan, push [FUNC] + [Y] or [Z] again.
If the same frequencies are programmed into a pair of
scan edges, programmed scan does not start.
For programmed scan, scan edges must be programmed
in advance. Program scan edges into regular memory
channels and set the channels as scan edges. (p. 17)
Memory (bank) scan
q Select memory mode with [V/M].
w Make sure the squelch is set to the threshold point.
Select automatic squelch (AUTO) or a level (19) where the
noise is muted. (p. 10)
e Select the desired memory bank in set mode, if desired.
See below for details.
r Push [FUNC] + [Y] or [Z] momentarily to start the memory
scan or memory bank scan.
Decimal point ashes while scanning.
•“”flashes during memory bank scan.
To change the scanning direction, rotate [DIAL].
If the pocket beep function is activated, the transceiver automat-
ically selects the tone squelch function when a scan starts.
t To stop the scan, push [FUNC] + [Y] or [Z] again.
DMemory bank selection
q Push [V/M] for 2 sec. to enter set mode.
w Rotate [DIAL] until BNK SC appears.
e While pushing [FUNC], rotate [DIAL] to select the desired
memory bank.
•“OFF scans memories in both banks;
BANK0 scans memories in bank 0
only (ch 0 to 99); BANK1 scans
memories in bank 1 only (ch 100 to
199).
r Push [V/M] to exit set mode.
Memory bank 0
(Memory ch 0 to 99)
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-Q7 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-Q7 in the language / languages: English as an attachment in your email.

The manual is 0,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info