9
AIS RECEIVER (Depending on versions)
New2001
D CPA/TCPA (Continued)
Slow Warn
The GPS receiver calculated COG data of a vessel that is at
anchor or drifting is unreliable, and therefore the CPA and
TCPA data may not be calculated correctly. If a vessel is an-
chored in your alarm zone, the unreliable data can cause the
collision alarm to sound many times, even if there is no real
danger. To prevent this, when the anchored vessel’s SOG is
less than this set value, the Slow Warn function assumes that
vessel’s COG is fixed towards your vessel and an alarm will
sound.
q
Rotate dial or push [Y]/[Z] to input the value between 0.1
and 4.9 kt (in 0.1 kt steps), or select OFF. (default: 1.0 kt)
w Push [ENT] to save and return to the Menu mode.
NOTE: If other vessels at anchor or drifting come into your
alarm zone, the Slow Warn alarm will sound again. Only if
the previous vessel disappears from the Danger List (p.
82), and then re-enters the list, can a new Slow Warn or
regular alarm sound, depending on the vessels SOG, or
CPA and TCPA. The Slow Warn function operates in the
same way if your vessel is at anchor and other vessels
enter your alarm zone area.
CPA, TCPA
Enter CPA (Closest Point of Approach) and TCPA (Time to
CPA) values.
These settings help you find a dangerous target to avoid a
collision. The icon blinks on the plotter display and/or the
alarm buzzer sounds, when the AIS target is closer than your
CPA and TCPA settings.
q
Rotate dial or push [Y]/[Z] to select either “CPA” or
“TCPA.
CPA or TCPA setting menu is displayed.
w Rotate dial or
push [Y]/[Z] to input the value into that
item.
CPA: Between 0.1 and 6.0 nm (in 0.1 nm steps)
(default: 1.5 nm)
TCPA: Between 1 and 60 minutes (in 1 minute steps)
(default: 20 min)
e
Repeat steps
q
and w to input the value into the other
item.
r Push [ENT] or dial to save and return to the Menu mode.
When the CPA setting
menu is selected.
When the TCPA setting
menu is selected.
96


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-M506 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-M506 in the language / languages: English as an attachment in your email.

The manual is 5,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info