13
MAINTENANCE
PROBLEM POSSIBLE CAUSE SOLUTION REF.
Troubleshooting
The following chart is designed to help correct prob-
lems which are not equipment malfunctions.
If you are unable to locate the cause of a problem or
solve it through the use of this chart, contact the near-
est Icom Dealer or Service Center.
Power does not come on
when [POWER] switch is
ON.
No sounds from the
speaker.
Sensitivity is low and
only strong signals are
audible.
Received signal cannot
be understood.
Output power is too low.
No contact possible with
another station.
<DC operation>
DC power cable is improperly connected.
<AC/DC common>
Fuse is blown.
•Volume level is too low.
The squelch is closed.
The audio mute function is activated.
•A selective call or squelch function is acti-
vated such as 2/5 tone call or tone squelch.
While in base operating mode, the repeater
is in the transmitting condition.
Antenna feedline or the antenna connector
has a poor contact or has short-circuited.
Optional voice scrambler is turned OFF.
Scrambler code is not set correctly.
Output power is set to Low.
The other station is using tone squelch.
While in base operating mode, the repeater
is set to duplex.
Re-connect the DC power cable correctly.
Check the cause, then replace the fuse with
a spare one. (Fuses are installed in the inter-
nal REG unit and LOGIC unit.)
Rotate [VOLUME] clockwise to obtain a suit-
able listening level.
While in base operating mode, rotate
[SQUELCH] counterclockwise to open the
squelch.
Push [SP MUTE] to turn the audio mute
function OFF
•Turn the appropriate function OFF.
Push [PTT] on the microphone to receive or
check the PTT line of an external unit, if con-
nected.
Check and re-connect (or replace if neces-
sary), the antenna feedline or antenna con-
nector.
•Turn the optional voice scrambler ON.
Reset the scrambler code.
Push channel selector to select the high
power operating channel.
•Turn the tone squelch function ON.
•Set the repeater to simplex, when the other
transceiver is set to simplex.
p. 6
p. 14
p. 12
p. 12
p. 1
p. 5
p. 1
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-FR3100 FR4100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-FR3100 FR4100 in the language / languages: English as an attachment in your email.

The manual is 1,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info