12346
70
Zoom out
Zoom in
Previous page
1/116
Next page
57
6
FUNCTIONS FOR TRANSMIT
2001 NEW 2001 NEW
Speech compressor
The speech compressor increases average RF output
power, improving signal strength and readability in
SSB, AM or FM.
When adjusting the compression level, it is necessary
to turn the COMP meter ON in the set mode, in ad-
vance (p. 81).
In SSB mode
q Select USB or LSB mode and adjust [MIC GAIN] to
a suitable level.
w While M1 is selected, push [F3 CMP] to turn the
speech compressor ON.
•“COMP appears.
e Push [F3 CMP] for 1 sec. to select compression
level set mode.
r While speaking into the microphone, rotate the tun-
ing dial, so that the COMP meter reads within the
COMP zone with your normal voice level.
Push [F3] for 1 sec. to select the default value.
When the COMP meter peaks above the COMP
zone, your transmitted voice may be distorted.
t Push [MENU] to return to M1.
In AM/FM mode
q While M1 is selected, push [F3 CMP] to turn the
speech compressor ON.
•“COMP appears.
w Push [F3 CMP] for 1 sec. and set the compression
level as 1 in advance.
e While speaking into the microphone, rotate [MIC
GAIN], so that the COMP meter does not exceed
the center dot whether you speak softly or loudly.
r While speaking into the microphone, rotate the tun-
ing dial, so that the COMP meter reads within the
COMP zone with your normal voice level.
Push [F3] for 1 sec. to select the default value.
When the COMP meter peaks above the COMP
zone, your transmitted voice may be distorted.
t Push [MENU] to return to M1.
Transmit lter width selection
(SSB mode only)
The transmit lter width for SSB mode can be selected
from wide, middle and narrow.
q Select USB or LSB mode.
w Push [MENU] to select M1, if necessary.
e Push [F4 TBW] for 1 sec. to select the transmission
passband width.
One of TX BW=WIDE, TX BW=MID or TX
BW=NAR is displayed for approx. 1 sec.
Transmit lter width: NAR 2.2 kHz
MID 2.4 kHz
WIDE 2.8 kHz
COMP
Level
COMP
Level
5
1
Compressor indicator
Shows compression level
COMP level zone
*The SWR meter functions as the COMP meter
when COMP meter is set to ON in the set mode.
COMP meter
ALC meter
Adjust the COMP Level with the tuning dial so
that the COMP meter does not exceed the COMP
level zone.
Adjust [MIC GAIN], so that the COMP meter does
not exceed this zone.
F 1
F
2F
3
F
4
F
5
F 1
F 2 F 3 F 4 F 5
AGC
DUP
CMP
TBW
SCP
AGC
DUP
CMP
TBW
SCP
TX
BW=WIDE
Push [F4]
Push [F4] for 1 sec. to select the transmit filter width.
The selected transmit filter width
is displayed for approx. 1 sec.
IC-7400.qxd 02.4.2 11:35 Page 57
70


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-7400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-7400 in the language / languages: English as an attachment in your email.

The manual is 5,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info