CONTROL CABLE SIGNALS
2001 NEW
Terminal information
Consider the following points when using a non-Icom
transceiver.
Start voltage [STAR]
When a start voltage (less than 1 V) is received, the
AT-140 begins automatic tuning.
Key voltage [KEY]
During automatic tuning, the AT-140 grounds the key
voltage line, and the HF transceiver reduces output
power.
If the key voltage is more than 8 V, switch the mode
switch (S1) to OFF mode (lower position).
8
6
4
2
0
Time
Key
voltage
[V]
Grounded
Approx. 7.5 V
During automatic tuning
8
6
4
2
0
Time
More than
350 msec.*
Approx. 7.5 V
Less than 1 V to
start tuning
Start
voltage
[V]
*For tuner through operation; Less than 250 msec.
[KEY]
[STAR]
[13.6]
[E]
*Connector shape may differ
according to version.
Terminal Description
[KEY] Key voltage. Grounded during tuning.
Max. current drain 100 mA.
[13.6] 13.6 V DC + input terminal.
Max. current drain 2 A
[STAR] Receives start voltage.
Max. current drain 1 mA
[E] Ground terminal for above signals.
Mode switch (S1)
[E]
[13.6]
[STAR]
[KEY]
NORMAL mode
OFF mode
S1
AT-140_1.qxd 04.4.26 9:16 Page 6
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom AT-140 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom AT-140 in the language / languages: English as an attachment in your email.

The manual is 0,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info