661331
17
Zoom out
Zoom in
Previous page
1/186
Next page
- 15 -
Note: This arrangement is only an illustrative example.
3.6 Adjusting the bypass
Optimal operation of the heat pump occurs when the cooling gas pressure is 22
2 bar.
This pressure can be read on the pressure gauge next to the control heat pump panel. Under these conditions the
water flow through the unit is also optimal.
Note: Operation without a bypass or with improper bypass adjustment may result in sub-optimal heat pump
operation and possibly damage to the heat pump, which renders the warranty null and void.
3.7 Electrical connection
Note: Although the heat pump is electrically isolated from the rest of the swimming pool system, this only
prevents the flow of electrical current to or from the water in the pool. Earthing is still required for protection
against short-circuits inside the unit. Always provide a good earth connection.
Before connecting the unit, verify that the supply voltage matches the operating voltage of the heat pump.
It is recommended to connect the heat pump to a circuit with its own fuse or circuit breaker (slow type; curve D)
and to use adequate wiring.
Connect the electrical wires to the terminal block marked POWER SUPPLY .
A second terminal block marked WATER PUMP is located next to the first one. The filter pump (max. 5 A / 240 V)
can be connected to the second terminal block here. This allows the filter pump operation to be controlled by the
heat pump.
Note: In the case of three-phase models, swapping two phases may cause the electric motors to run in the reverse
direction, which can lead to damage. For this reason, the unit has a built-in protective device that breaks the circuit
if the connection is not correct. If the red LED above this safety device lights up, you must swap the connections of
two of the phase wires.
3.8 Initial operation
Note: In order to heat the water in the pool (or hot tub), the filter pump must be running to cause the water to
circulate through the heat pump. The heat pump will not start up if the water is not circulating.
After all connections have been made and checked, carry out the following procedure:
1. Switch on the filter pump. Check for leaks and verify that water is flowing from and to the swimming pool.
Out In
Heat Pump
Use the following procedure to adjust
the bypass:
fully open all three valves
slowly close valve 1 until the
water pressure is increased by
approximately 100 to 200 g
Close valve 3 approximately
half-way to adjust the gas
pressure in the cooling system
If the display shows "ON" or
error code EE3, close step by
step the valve 2, to increase
water flow and stop when the
code disappear.
To pool
From pool
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hydro-Pro Inverter 10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hydro-Pro Inverter 10 in the language / languages: English, German, Dutch, Danish, French, Polish as an attachment in your email.

The manual is 4,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info