661330
25
Zoom out
Zoom in
Previous page
1/186
Next page
- 23 -
Hold and for 5 seconds to lock/Unlock the display.
Water temperature setting :
Press
or
to set the water temperature directly.
Parameter checking :
Press first, then press to check the User parameter from d0 to d11
Code
Condition
Scope
Remark
d0
IPM mould temperature
0-120
Real testing value
d1
Inlet water temp.
-9℃~99
Real testing value
d2
Outlet water temp.
-9℃~99
Real testing value
d3
Ambient temp.
-30
℃~
70
Real testing value
d4
Return gas temp.
-30℃~70
Real testing value
d5
Piping temp.
-30℃~70
Real testing value
d6
Gas exhaust temperature
0℃~C5 (125)
Real testing value
d7
Step of EEV
0
99
N*5
d8
Compressor running frequency
099Hz
Real testing value
d9
Compressor current
030A
Real testing value
d10
Current fan speed
0-1200 rpm
Real testing value
d11
Error code for last time
All error code
Press first, then press to check/adjust the User parameter from P1 to P7
Code
Name
Scope
Default
Remard
P1
Working mode
0-1
1
1 Heating mode
0 cooling mode
P2
Timer on/off
0-1
0
1 Timer on/off is under function
0 Timer on/off is out of
function (The setting of P4 and P5 won’t work)
P3
Water pump
0-1
0
1 Always running
0 Depends on the running of compressor
P4
Current time
HH:MM
0000
0-23:0-59
P5
Timer on
HH:MM
0000
0-23:0-59
P6
Timer off
HH:MM
0000
0-23:0-59
P7
Inlet water temp.
correction
-99
0
Default setting: 0
6.2.4 System reset function
Press and in 10s, the system will reset and display “0000 on the controller.
6.2.5
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hydro-Pro Inverter 07 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hydro-Pro Inverter 07 in the language / languages: English, German, Dutch, Danish, French, Polish as an attachment in your email.

The manual is 4,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info