- 19 -
Water Inlet & outlet junction
1. Use the pipe tape to connect the
water Inlet & outlet junction onto the
heat pump
2. Install the two joints like the
picture shows
3. Screw them onto the water Inlet &
outlet junction
10M Signal wiring
1. Take one side of the 10M Signal
wire, to connect with the controller.
2. The other side needs to be pulled
through the hole, like the third
picture shows.
3. Then connect to the PC board
inside the machine : the brown one
--- first joint; the blue one --- second
joint; the yellow one --- third joint.
Cable wiring
1. Connect the power supply wire
through the white hole like the
picture shows.
2. Fix the other side on joints inside
the electric box.
Water pump wiring
1. Connect the water pump wire
through the white hole marked
2. Fix the other side on joints inside
the electric box.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hydro-Pro 22T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hydro-Pro 22T in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 14,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hydro-Pro 22T

Hydro-Pro 22T Usermanual and installation guide - Dutch - 35 pages

Hydro-Pro 22T User Manual - Dutch - 27 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info