Installation manual
Legislation
If the stove insert is to be mounted in a newly built, non-approved open fireplace, all legal
requirements and local building regulations must be observed. It would always be advantageous
to consult your chimney sweep before mounting the stove insert. He is, after all, the one who
will be sweeping the chimney.
Room requirements
There must be a constant supply of fresh air to the room in which the stove is to be installed. A
window that opens or an adjustable air vent should suffice.
Load-bearing capacity of floor
Before installing the stove insert, you must ensure that the load-bearing capacity of the floor can
withstand the weight of the stove and the chimney. The weight of the stove insert is indicated
in the brochure, and that of the chimney should be calculated according to its dimensions and
height.
Distance to inflammable materials (Drawing C)
As the stove insert is usually mounted in an existing fireplace, the requirements regarding
distances to inflammable materials as well as the non-combustible area on the floor are always
observed.
In the case of a new construction, however, please refer to the local building regulations regarding
the size of the non-combustible area in front of the fireplace. If the stove insert is to be mounted
up against inflammable material, the outer casing should be insulated on the outside using fire
batts with a min. thickness as shown on the dimensioned sketch. The sides should be insulated
with a thickness of min. 50 mm.
Chimney requirements
The chimney must be of a sufficient height to enable an adequate draft and to prevent smoke
problems. Nominal draft: approx. 15 Pa.
The chimney must have a minimum opening equivalent to Ø 15 cm.
The chimney opening should always be at least the size of the outlet socket of the stove.
The chimney must have an easily accessible soot door.
Chimney
The chimney is the “motor” of the stove and it is crucial for the functioning of the woodburning
stove. The chimney draft provides a partial vacuum in the stove. This vacuum removes the smoke
from the stove, sucks air through the dampers for the so-called glass pane rinse which keeps
the glass free of soot, and sucks in air through primary damper for the combustion.
The chimney draft is created by the differences in temperature inside and outside the chimney.
The higher the temperature within the chimney, the better the draft. It is crucial, therefore, that
the chimney is warmed through properly before closing the damper and limiting the combustion
in the stove (a brick chimney takes longer to warm through than a steel chimney).
Even a good chimney can function badly if it is not used correctly. Similarly, a bad chimney may
function well if it is used correctly.
English
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hwam Classic 10-50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hwam Classic 10-50 in the language / languages: English, German, Danish, Swedish as an attachment in your email.

The manual is 1,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hwam Classic 10-50

Hwam Classic 10-50 User Manual - Dutch, French, Italian, Spanish - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info