571943
18
Zoom out
Zoom in
Previous page
1/60
Next page
Installation
Legislation
Installation of your woodburning stove must always comply with local building regulations.
It is a good idea to consult with your local chimney sweep before installing, since he will
be the one to sweep the chimney and stove.
Room requirements
There must be a constant supply of fresh air to the room in which the stove is to be
installed. A window that opens or an adjustable air vent should suffice, but it is also
possible to connect the stove to an ABC fresh air system.
Load-bearing capacity of floor
Before installing the stove, you must ensure that the load-bearing capacityof the floor
can withstand the weight of the stove and the chimney. The weight of the stove is
indicated in the brochure, and that of the chimney should be calculated according to
its dimensions and height.
Distance to inflammable materials
Your ABC woodburning stove should always be installed on a non-combustible hearth. If it
is installed on a wooden floor or similar, the floor must be covered with a non-combustible
material to a distance of 30 cm in front of the stove and 15 cm to each side measuring
from the door of the combustion chamber. A 2 mm thick ABC stove hearth will, in addition,
cover the area underneath the stove.
Chimney requirements
The chimney must be of a sufficient height to enable an adequate draft and to prevent
smoke problems.
The chimney must have a minimum opening equivalent to Ø 15 cm. The chimney opening
should always be at least the size of the outlet socket of the stove. The chimney must
have an easily accessible soot door.
Air damper
We recommend that the chimney or the pipe is equipped with a damper so that the
chimney draught can be regulated on days with strong winds. It is not allowed that the
damper close the pipe totally. There must always be a free area of min. 20% of the total
opening of the chimney or the pipe.
Requirements to smoke gas damper
If a smoke gas damper is mounted, it must be manually operated as well as easy to
operate. Its position must be visible and stable. The damper must not be capable of
closing completely tight. This is ensured by a cutting out in the damper of at least 20% of
the damper’s the area, however at least 20 cm
3
.
18
English
ABC model no. 1 7H 14 17
Chimney draft nominal Pa. 11 15 13 15
ABC model no. (Sectional view A on page 3) 1 7H 14 17
1. Recommended for brick wall, cm 10 10 10 10
1. For inflammable back wall, cm 20 20 20 20
2. For inflammable side wall, cm 25 25 25 25
3. Fireproof area in front, cm 30 30 30 30
4. Fireproof area in front, cm 73 77 77 77
5. From opening to edge of plate, cm 15 15 15 15
6. Distance to furnishings in front, cm 80 80 80 80
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hwam ABC 14 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hwam ABC 14 in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Spanish, Norwegian as an attachment in your email.

The manual is 1,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info