744538
9
Zoom out
Zoom in
Previous page
1/20
Next page
9
For UK - The Clean air aCT 1993 and SmoKe ConTrol areaS
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority
to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace
or from any xed boiler if located in a designated smoke control area. It is also an offence to acquire
an ”unauthorised fuel” for use within a smoke control area unless it is used in an ”exempt” appliance
(”exempted” from the controls which generally apply in the smoke control area).
In England appliances are exempted by publication on a list by the Secretary of State in accordance with
changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act
2015. Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under
section 50 of the Regulatory Reform (Scotland) Act 2014. In Northern Ireland appliances are exempted
by publication on a list by the Department of Agriculture, Environment and Rural Affairs under Section
16 of the Environmental Better Regulation Act (Northern Ireland) 2016. In Wales these are authorised
by regulations made by Welsh Ministers.
Further information on the requirements of the Clean Air Act can be found here: https://www.gov.uk/
smoke-control-area-rules. Your local authority is responsible for implementing the Clean Air Act 1993
including designation and supervision of smoke control areas and you can contact them for details of
Clean Air Act requirements.
The HWAM 4500 stoves detailed below have been recommended as suitable for use in smoke control
areas when burning wood logs. The appliance has been tted with a modied secondary air control to
prevent closure of the air inlet below 20 %.
Appliances recommended as suitable for use in Smoke Control Areas :
HWAM 4510c/4510m
HWAM 4520c/4520m
HWAM 4530c/4530m
HWAM 4540c/4540m, HWAM 4540c/4540m with soapstone, HWAM 4540c/4540m with sandstone
HWAM 4550c/4550m
HWAM 4560c/4560m, HWAM 4560c/4560m with soapstone, HWAM 4560c/4560m with sandstone
Refuelling on to a low re bed
If there is insufcient burning material in the rebed to light a new fuel charge, excessive smoke emission
can occur. Refuelling must be carried out onto a sufcient quantity of glowing embers and ash that the
new fuel charge will ignite in a reasonable period. If there are too few embers in the re bed, add suitable
kindling to prevent excessive smoke.
Fuel overloading
The maximum amount of fuel specied in this manual should not be exceeded, overloading can cause
excess smoke.
Operation with door left open
Operation with the door open can cause excess smoke. The appliance must not be operated with the
appliance door left open except as directed in the instructions.
Dampers left open
Operation with the air controls or appliance dampers open can cause excess smoke. The appliance must not
be operated with air controls, appliance dampers or door left open except as directed in the instructions.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hwam 4530 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hwam 4530 in the language / languages: English as an attachment in your email.

The manual is 0,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hwam 4530

Hwam 4530 User Manual - German - 20 pages

Hwam 4530 User Manual - Dutch, French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info