744536
11
Zoom out
Zoom in
Previous page
1/20
Next page
11
If there is risk of embers falling under the stove, the non-combustible material must also cover the oor
under the entire bottom plate of the stove as well as the area next to the stove in accordance with
national rules. The non-ammable material must be of a size that is sufcient to prevent embers from
falling out on the combustible oor.
Min. distances - uninsulated ue gas pipe:
(drawing A)
With steel cladding With stone
cladding
HWAM 4510
HWAM 4530
HWAM 4550
HWAM 4520
HWAM 4540
HWAM 4560
HWAM 4540
HWAM 4560
1. Recommended for brick wall, back, cm
10 10 10
2. Recommended for brick wall, side, cm
30 10 10
1. For inammable wall, back, cm
10 10 10
2. For inammable wall, side, cm
59 35 40
1.To inammable wall, corner installation, cm
33 7 7
3. Distance to furnishings in front, cm
120 110 110
IMPORTANT FOR UK (for all other countries please see separate text below)
In case of wall installation, HWAM 4510/4520 must be suspended at least 17.5 cm above
an inammable oor (measured from the bottom plate of the stove). The above require-
ment applies even if the oor is tted with a oor plate.
The variant HWAM 4510/4520 without a plinth must be installed on a BS non combustible/
constructional hearth. The non combustible/constructional hearth must extend 425 mm
in front of the appliance. It is still considered a combustible oor even if an ember catch-
ing, non-combustible oor plate is placed on top of the combustible oor. Floor in front
exceed 100°C demand closer than 425 mm in front of the stove installed without a plinth.
Floor directly beneath the stove installed without a plinth does exceed 100°C.
Take note of the applicable regulations for the distance between the wall and ue pipe.
The distance to a brick wall is set to faciliate the servicing of the Autopilots system.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a ammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
IMPORTANT FOR ALL COUNTRIES BUT UK (for UK please see separate text above)
In case of wall installation, HWAM 4510/4520 must be suspended at least 28.5 cm above
an inammable oor (measured from the bottom plate of the stove). The above require-
ment applies even if the oor is tted with a oor plate.
HWAM 4510/4520 without a plinth and HWAM 4510/4520 with a low plinth must not be
mounted on combustible oors. It is still considered a combustible oor even if an ember
catching, non-combustible oor plate is placed on top of the combustible oor.
A non-combustible structure under HWAM 4510/4520 without a plinth and HWAM
4510/4520 with a low plinth must extend at least 480 mm in front of the stove.
Take note of the applicable regulations for the distance between the wall and ue pipe.
The distance to a brick wall is set to faciliate the servicing of the Autopilots system.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a ammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hwam 4510 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hwam 4510 in the language / languages: English as an attachment in your email.

The manual is 0,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hwam 4510

Hwam 4510 User Manual - German - 20 pages

Hwam 4510 User Manual - Dutch, French - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info