744530
11
Zoom out
Zoom in
Previous page
1/20
Next page
Page 11 of 20 pages
Model Weight Height Width Depth
HWAM 4110 / HWAM 4120 135 kg
102,7 cm
51,0 cm 51,0 cm
HWAM 4130 / HWAM 4140 145 kg
119,3 cm
51,0 cm 51,0 cm
HWAM 4150 / HWAM 4160 170 kg
162,1 cm
51,0 cm 51,0 cm
HWAM 4240 140 kg
112,4 cm
54,3 cm 45.5 cm
HWAM 4240 with natural stone cladding 191 kg
116,6 cm
54,3 cm 45,5 cm
HWAM 4240 with soapstone cladding 215 kg
116,6 cm
54,3 cm 45,5 cm
Heat storing slabs HWAM 4150/4160 30/60/90 kg
Floor plate
European, national and local regulations must be observed in terms of the size and thickness of a non-
combustible floor covering the floor in front of the combustion chamber opening. Ask your HWAM
retailer for assistance. The combustion chamber opening is 28.4 cm wide.
Distance to inflammable materials
Your HWAM woodburning stove should always be installed on a non-combustible hearth. If it is installed
on a wooden floor or similar, the floor must be covered with a non-combustible material.
Min. distances - uninsulated flue gas pipe
(drawing A)
HWAM 4110
HWAM 4130
HWAM 4150
HWAM 4120
HWAM 4140
HWAM 4160
HWAM 4240
1. Recommended for brick wall 10 cm 10 cm 10 cm
1. For inflammable back wall 15 cm 10 cm 10 cm
2. For inflammable side wall 42 cm 42 cm 42 cm
1.To inflammable wall,corner installation, 45º 10 cm 10 cm 10 cm
3. Distance to furnishings in front 110 cm 90 cm 90 cm
Min. distances - insulated flue gas pipe
(drawing A)
HWAM 4110
HWAM 4130
HWAM 4150
HWAM 4120
HWAM 4140
HWAM 4160
HWAM 4240
1. Recommended for brick wall 10 cm Nicht getestet Nicht getestet
1. For inflammable back wall 10 cm Nicht getestet Nicht getestet
2. For inflammable side wall 42 cm Nicht getestet Nicht getestet
1.To inflammable wall,corner installation, 45º Nicht getestet Nicht getestet Nicht getestet
3. Distance to furnishings in front 110 cm Nicht getestet Nicht getestet
Remember to pay attention to applicable regulations concerning the required distance
between the wall and smoke pipe.
The distance to a brick wall is set to faciliate the servicing of the HWAM
®
Autopilot™ system.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a flammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
The height of the chimney must ensure sufficient draught and prevent any smoke nuisance. As a general
rule, satisfactory draught conditions are achieved if the chimney is 4 m above the stove and at least 80
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hwam 4120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hwam 4120 in the language / languages: English as an attachment in your email.

The manual is 1,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hwam 4120

Hwam 4120 User Manual - German - 20 pages

Hwam 4120 User Manual - Dutch - 20 pages

Hwam 4120 User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info