FIrIng In general
Rapid or fierce heat
Rapid or fierce heat is obtained by burning many small pieces of wood.
Maximum amounts of fuel:
The maximum allowed amount of fuel per hour is:
Wood: 2.0 kg Briquettes: 1.6 kg
Typical re-firing interval at nominal performance
Wood: 65 min Briquettes: 65 min
If these limits are exceeded, the stove will no longer be covered by the factory guarantee, and it may also
become damaged due to excessive heat. The stove has been approved for intermittent use.
Long burning times
For the slowest possible combustion, move the regulation lever all the way down. By moving the lever all
the way down, the stove receives no primary air (air that comes through the grate). The stove cannot be
lit after a new firing without the regulation lever being moved up, which allows primary air to enter.
By positioning the lever approx. ¼ above the minimum setting (approx. 25% capacity), the stove can restart
following a new firing without further regulation.
Insufficient firing
If the fireproof materials in the combustion chamber are blackened after a fire, then the stove is polluting,
and the automatic air flow regulation system is malfunctioning. Therefore, more air must be supplied by
moving the regulation lever upwards. It may also be necessary to burn more wood.
How to achieve the best combustion
Use clean and dry wood.
Wet wood results in inefficient combustion, plenty of smoke, and soot. Furthermore, the heat will dry
the wood, not heat up the room.
The fire should only be stoked with a little wood at a time.
You achieve the best combustion by starting up a fire often and using only a little wood. If you use
too much firewood, it will take some time before the temperature reaches a level where you achieve
a good combustion.
Make sure there is the right amount of air.
You should also make sure that there is plenty of air – especially in the beginning - so the tempera-
ture in the wood burning stove climbs quickly. In this way the gasses and particles released during the
combustion will be consumed by the fire. Otherwise they build up soot in the chimney (constituting
a chimney fire risk) or will be released in a non-combusted state into the environment. The wrong
amount of air supply creates inefficient combustion and a modest effect.
Don’t savour the fire during night time
We advise against adding fire wood to your stove and reducing the air supply at night in an attempt
to still have some embers left in the morning. If you do so, large amounts of hazardous smoke will be
emitted, and your chimney will be exposed to unnecessarily large amounts of soot with the risk of a
chimney fire.
Cleaning the glass
We recommend wiping the glass after a fire. This is best done using a paper towel.
Downloaded from www.Manualslib.com manuals search engine
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hwam 3530 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hwam 3530 in the language / languages: English, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 1.56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hwam 3530

Hwam 3530 User Manual - German - 44 pages

Hwam 3530 User Manual - Dutch, French - 32 pages

Hwam 3530 User Manual - Italian, Spanish - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info