571932
38
Zoom out
Zoom in
Previous page
1/48
Next page
38
The smoke shelf (5). To be placed on top of the steel rail and on the holders in the sides.
Two-piece smoke defector plate (6). Each half is hung on the hooks located beneath the top plate. The two
halves join in the holders behind the air pipe. Once the stove has been installed, twist the protection off
the two hooks by using pliers or a screwdriver.
Cover plate (7). Should always cover the grate.
Removable rear plate (2), covering automatic controls. This must always be mounted if the stove is
placed next to a combustible wall.
Loose heat shield (8) under the ash pan. This can be used as a lid when the ash pan is removed for
emptying.
Cover plate (Drawing D)
Your HWAM woodburning stove is supplied with a loose cover plate for the shaking grate. This is a 3
mm thick iron plate. It is placed on top of the shaking grate and prevents the embers from falling into
the ash pan. The cover plate is raised approx. 8 mm above the grate, thus ensuring that the automatically
controlled primary combustion air is distributed evenly at the base of the combustion chamber.
Chimney
The chimney is the “engine” of the stove and it is crucial for the functioning of the woodburning stove.
The chimney draft provides a partial vacuum in the stove. This vacuum removes the smoke from the stove,
sucks air through the dampers for the so-called glass pane rinse which keeps the glass free of soot, and
sucks in air through both primary and secondary dampers for the combustion.
The chimney draft is created by the differences in temperature inside and outside the chimney. The higher the
temperature within the chimney, the greater the draft. It is crucial, therefore, that the chimney is warmed up
properly before closing the damper and limiting the combustion in the stove (a brick chimney takes longer to
warm up than a steel chimney). On days where the weather and wind conditions create insufcient draught
inside the chimney, it is even more important to warm up the chimney as quickly as possible. The trick is to
quickly get some ames going. Split the wood into extra ne pieces, use an extra relighter, etc.
If the stove has not been used for a longer period, it is important to check that the chimney pipe is not
blocked.
It is possible to connect several devices to the same chimney. However, it is important to first check the
applicable rules.
Even a good chimney can function badly if it is not used correctly. Similarly, a bad chimney may function
well if used correctly.
Chimney sweeping
To prevent the risk of chimney fires, the chimney must be cleaned every year. The flue duct and the smoke
chamber above the baffle plate must be cleaned together with the chimney. If the chimney is too tall to
be cleaned from above, it must be equipped with a soot door.
In case of a chimney fire, close all dampers and call the firefighters. Before any further use, have the
chimney checked by the chimney sweeper.
Test results from nominal test EN 13240
Nominal heating effect 4.5 kW
Smoke temperature 254ºC
Exhaust gas flow 5.1 g/s
All manuals and user guides at all-guides.com
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hwam 3420S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hwam 3420S in the language / languages: English, Danish, Swedish, Norwegian as an attachment in your email.

The manual is 1.54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hwam 3420S

Hwam 3420S User Manual - German, Dutch, French, Italian, Spanish - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info