maIntenance
Cleaning
Any maintenance of the stove should only be carried out when it is cold. Daily maintenance is limited to
vacuum cleaning the stove externally, using the soft brush attachment. You can also dust the stove using a
dry, soft cloth or brush. But remember, only when the stove is cold. Do not use water, spirit or any other
kind of cleaner, as this will damage the lacquer.
Once a year, the stove should be thoroughly serviced. The combustion chamber should be cleared of ashes
and soot. The hinges and the closing hook must be greased with liquid copper fat spray (heat-resistant up to
1100 degrees Celsius), see drawing H. Lift the door approx. ½ cm and spray copper fat onto the hinge leaf.
Service inspection
Your stove should be given a thorough, preventive inspection once every two years. This includes:
Thorough cleaning of the stove
Check the spring in the HWAM
®
Autopilot™ and replace if necessary
Checking gaskets. Replace gaskets if they are not intact or have softened
Checking of heat insulating material and possibly replacement
Lubricating the hinges and the locking hook with cobber grease (drawing H)
All service checks must be performed by an authorised fitter. Use only original spare parts
Inside cleaning
Before chimney sweeping can be performed, the air control knob must be set to its minimum position to
prevent soot and ash from entering the HWAM
®
Autopilot™. Unless the safety fittings for transportation
have not already been removed, the safety fittings for transportation is bent downwards/forwards until it
is vertical (drawing B, 6a).
The smoke shelf and baffle plate is to be removed from the stove before cleaning
(drawing E)
Lift the smoke shelf (1) up and a little forward, so it is detached from the uppermost rear plate (2). The
smoke shelf can now be lowered and removed.
• Lift the baffle plate (3) up a little and move it forward until it is detached from the hooks in each side.
After sweeping, reinstall the parts in the stove in reverse order.
Ashes
The ash pan is best emptied by pulling a waste bag over the pan, tipping it and then carefully pulling it out
of the bag. Ashes are disposed of via the domestic waste collection.
Please note that there may be embers in the ashes for up to 24 hours after the fire has
gone out!
Insulation
The efficient, but porous insulation of the combustion chamber may, in time, be worn and damaged. Cracks
in the insulation are irrelevant to the efficiency of the stove. However, it should be replaced, if there are
actual holes due to parts of the lining falling off or when, due to wear and tear, it has been reduced to
less than half its original thickness.
HWAM Autopilot
TM
(Drawing F)
Lift off the rear panel. On a cold stove, the starting point of the feeler is controlled. The starting point of
the feeler when the stove is cold is approx. 20° below horizontal level, pointing to the left (by the grove
in the oval steel plate).It should feel easy going and bouncy when you push it, no matter if the stove is
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hwam 2600 series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hwam 2600 series in the language / languages: English as an attachment in your email.

The manual is 1,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hwam 2600 series

Hwam 2600 series User Manual - German - 52 pages

Hwam 2600 series User Manual - German - 20 pages

Hwam 2600 series User Manual - Dutch, French - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info