809499
14
Zoom out
Zoom in
Previous page
1/32
Next page
14
Intelligenzia Range C4PRO-IT, C5PRO-IT, C8PRO-IT, & C10PRO-IT
EVAPORATOR FAN
As part of the chiller’s normal operation the evaporator fan will switch off automatically when
the door is opened. The switch is located in the top of the door rebate (see Fig. 6 on page 13).
INSTALLING SHELVES
Fit the shelf clips to the ladder racks (see Fig. 2 on page 13) and install the shelves horizontally.
Ensure the clips are located firmly and the shelves are secure before loading the chiller.
FITTING/REMOVING THE ILLUMINATED CANOPY
QUALIFIED ENGINEERS ONLY. To fit the canopy, first disconnect the chiller from the power
supply. Remove the right hand door hinge cover. Plug the canopy into the socket that may now
be seen. See Fig. 1 on page 13. Tighten the thumb screws on both sides of the canopy to secure
the canopy to the chiller. Re-connect the chiller to the power supply.
To remove the canopy, first disconnect the chiller from the power supply. Loosen the thumb
screws on both sides of canopy, then pull out the plug for the canopy light – see Fig. 1 on page
13. The canopy may now be removed. Re-fit the right hand door hinge cover. Finally
re-connect the chiller to the power supply.
EASY MAINTENANCE ACCESS
QUALIFIED ENGINEERS ONLY. Husky chillers are designed for easy maintenance. One
feature is that the compressor, condenser and condenser fan are mounted on an easily-
accessible sliding tray. To access this sliding tray, open the door(s) fully and loosen the two
screws (which have now become accessible) on the top on either side of the kick plate – see Fig
5 on page 13. Remove the kick plate by lifting it up and pulling it forward. Loosen the thumb
screws on either side of the sliding tray – see Fig. 4 on page 13. With caution slide out the sliding
tray no more than 300mm.
COMPRESSOR
QUALIFIED ENGINEERS ONLY. To access the compressor, slide out the sliding tray – see ‘Easy
Maintenance Access’.
CLEANING
The condenser and the compressor compartment MUST be cleaned quarterly – see ‘Easy
Maintenance Access’ how to access the compressor compartment.
The external and internal surfaces of the unit should be cleaned regularly. Switch the unit off
and disconnect the plug from the mains socket. Remove the drainage hole cover (see Fig. 3 on
page 13). Clean the external and internal surfaces of the unit with a mild soap solution, then
wipe dry. Replace the drainage hole cover. Do NOT use cleansers containing chlorine or other
harsh cleansing agents, as these can damage the stainless steel surfaces and components. Use
mild soapy water to clean the gasket and seals.
GETTING SERVICE ASSISTANCE
The cooling system is a hermetically sealed circuit and does not require any maintenance other
than regular cleaning (see ‘Cleaning’).
If the unit fails to work, first check the power supply. If you cannot locate the reason for the
failure, please contact your supplier, stating the model and serial number of the cabinet. You
may find this information on the rating plate, which is affixed inside the unit on the top right-hand
interior wall.
International PRO upright manual 240317 EDITION 2 v2.indd 14 28/03/2017 08:34
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Husky F5PRO-H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Husky F5PRO-H in the language / languages: English as an attachment in your email.

The manual is 7.09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info