AC solenoid valves with controllers. The example in the chart below demonstrates the most
commonly used wire size for station control and ground wire ( e.g.,12 AWG = 3390 feet).
NOTE: Valve Wire Sizing (Maximum One-Way Distance in Feet Between Controller and
Valve)
Ground
Wire
(size)
Control Wire (FT)
18 AWG / 1.0
mm
16 AWG / 1.2
mm
14 AWG / 1.6
mm
12 AWG / 2.0
mm
10 AWG / 2.5
mm
8 AWG / 3
mm
18 AWG / 1.0
mm 850 1040 1210 1350 1460 1540
16 AWG / 1.2
mm 1040 1340 1650 1920 2150 2330
14 AWG / 1.6
mm 1210 1650 2150 2630 3080 3450
12 AWG / 2.0
mm 1350 1920 2630 3390 4170 4880
10 AWG / 2.5
mm 1460 2150 3080 4170 5400 6670
8 AWG / 3 mm 1540 2330 3450 4880 6670 8700
Pump Start Relay Wiring and
Software Setup
In this article, we will discuss the following topics:
Summary
Operation Chart
Wiring (24 VAC)
Wiring to Power Source
Copyright 2023 Hunter Industries. All Rights Reserved. 22
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hunter Hydrawise App at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hunter Hydrawise App in the language / languages: English as an attachment in your email.

The manual is 4.42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info