WATER DAYS
SEASONAL ADJUSTMENT
WATER DAYS
SEASONAL ADJUSTMENT
Valve Common Wire
Connect the Two
Transformer Wires to
the Two AC Terminals
Valve 1
Valve
2
Valve 3
Valve 4
Valve
Wires
654321PC
SEN
RS
T
AC
9 V Battery
8
CONNECTING VALVES AND TRANSFORMER ....................................................................
1. Route control wires between valve location and controller. Typi-
cally it is recommended that at least 1 mm diameter conductor
cable be used. This type of cable is insulated for burial and is
color-coded to help keep track of your connections.
2. At the valves, attach the common wire to either solenoid wire of
the valve. This is most commonly a white colored wire. Attach a
separate control wire to the remaining solenoid wire and make a
note of the color corresponding to each valve and the watering
station it controls.
3. Secure the wires with a waterproof wire connector to protect the
connection.
4. Slide down wiring compartment door to access the terminal strip
area shown in the diagram.
5. Route the valve wires into the cabinet. Strip 5 mm of insulation
from ends of all wires.
6. Secure the white valve common wire to the screw on the terminal
marked C. Connect the color-coded wires from the valves to their
appropriate station numbers and tighten the screws.
7. For the indoor model,
route transformer cable
through the left side of the
controller and connect the
wires to the two screws
marked AC.
8. Before closing the com-
partment door make sure
wires hang in the slotted
areas so that the door can
snap shut without damag-
ing wires.
9. For the outdoor model, transformer wires are already connected to
the AC slots so all that is required is to connect primary power to
the junction box from a power source.
10. Remove junction box cover and attach power wires to either screw
slot. Be sure to use a code approved conduit and adapter for the
primary wires.
Do not plug transformer into power source until the con-
troller is mounted and all valves have been connected.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hunter EC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hunter EC in the language / languages: English as an attachment in your email.

The manual is 0,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hunter EC

Hunter EC User Manual - German - 16 pages

Hunter EC User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info