SOLAR SYNC
Aer connecting a Solar Sync sensor to the controller, set up
operation in the Devices, Solar Sync menu.
Check the box to Enable Solar Sync.
Choose the Region and set the Water Adjustment,
according to the Solar Sync manual instructions.
For normal operations, this is all that is necessary. It will
take the Solar Sync two or three days to register enough
climate data to begin adjusting.
Solar Sync Delay allows a number of days to wait before
automatic Solar Sync adjustment goes into eect (to establish
new landscape, for example). Enter a number of days (1-250)
to wait, and specify the Adjustment During Delay percentage
to use during the delay period. At the end of the delay, the
Solar Sync will begin adjusting automatically for the current
climate conditions.
The delay does not interfere with the Solar Sync Rain and
Temp functions. They are still able to perform shutdowns on
rain or freeze events during this delay.
Complete the setup by setting the programs to use Solar Sync
in the Program, Seasonal Adjust menu.
FLOW SENSORS
Aer connecting one or more ow sensors to the controller,
set up operation in the Devices, Flow Sensors menu.
Select the sensor input number to be setup (1-6). The
controller has 3 Flow Sensor inputs built in, but 3 more can be
added with the A2C-F3 Flow Expansion module.
Check the box for either “Hunter” or “Other” ow meters.
If Hunter is checked, move to the Model eld and select the
Hunter FCT model number for the diameter of the pipe. This is
all that is necessary to calibrate the setup.
If Other is checked, you must select the Flow Sensor Style
and enter the calibration information. Some use K-factor and
Oset, and others are Pulse type. Consult the ow meter
suppliers documentation for the correct settings or contact
Hunter Technical Support for additional information.
K-Factor and Offset: obtain these values from the ow sensor
manual, and enter here.
Basic Programming and Setup
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hunter ACC-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hunter ACC-2 in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Hunter ACC-2

Hunter ACC-2 Quick start guide - German - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info