Speed Calibration
(Advanced, with Temp/Speed only)
Speed Calibration will adjust the speed readout by the percentage entered, and will appear
in the menu if a Temp/Speed Accessory is connected and the paddlewheel has moved at
least once, when the unit is in Advanced User Mode (see Setup Menu Tab: User Mode.)
To change the Speed Calibration setting:
1. Make sure you are in Advanced User Mode, then highlight Speed Calibration on
the Setup menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Speed
Calibration setting. (-20% to +20%, Default = 0%)
Local Time Zone
(Advanced)
Local Time Zone selects your time zone in reference to the time reported by the GPS
receiver when Time+Date is selected as a Digital Readout on the Sonar View (see Select
Readouts). This menu choice is available only when in Advanced User Mode (see Setup
Menu Tab: User Mode).
To change the Local Time Zone:
1. Make sure you are in Advanced User Mode, then highlight Local Time Zone on
the Setup menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Local Time Zone
(Default = EST [UTC-5] - Eastern Standard Time).
97
To Select R
eadouts:
1. Make sure you are in Advanced User Mode, then highlight Select Readouts on
the Setup main menu.
2. Use the RIGHT 4-WAY Cursor Control key to initiate this procedure.
3. The Select Readouts submenu will appear, showing a list of all Readouts. Use
the UP or DOWN Cursor keys to select a particular Readout position, then use
the RIGHT or LEFT Cursor keys to change what will be displayed at that
position. (Course, Navigation, Position, Off, Speed, Temperature, Time+Date,
Triplog, Voltage)
Depth Offset
(Advanced)
Depth Offset will adjust the digital depth readout to indicate depth from the waterline
or boat's keel. Enter a positive vertical measurement from the transducer to the
waterline to read the depth from the waterline. Enter a negative vertical measurement
from the transducer to keel to read the depth from the keel. This menu choice is
available only when in Advanced User Mode (see Setup Menu Tab: User Mode.)
T
o change the Depth Offset setting:
1. Make sure you are in Advanced User Mode, then highlight Depth Offset on the
Setup menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Depth Offset
setting. (-10.0 to +10.0 feet or -3 to 3 meters [International Models only], Default = 0)
Temp Offset
(Advanced)
Temp Offset will adjust the temperature readout by the amount entered. This menu
choice is available only when in Advanced User Mode (see Setup Menu Tab: User Mode.)
T
o change the Temp Offset setting:
1. Make sure you are in Advanced User Mode, then highlight Temp Offset on the
Setup menu.
2. Use the LEFT or RIGHT 4-WAY Cursor Control keys to change the Temp Offset
setting. (-10.0 to +10.0 degrees, Default = 0)