743661
8
Zoom out
Zoom in
Previous page
1/28
Next page
© 2009 HRsolar
8
Installatie van indirect gestookte boiler
Monteer het zonzijdige gedeelte volgens installatie instructies zonzijdig
Monteer de meegeleverde 3wegklep in de aanvoerleiding van de cv toestel
Sluit de derde poort van de 3wegklep aan op de bovenste aansluiting van de bovenste spiraal
Sluit de onderzijde van het spiraal op de retourleiding van de cv toestel
Sluit de rvs ½ voelerbuis met sensor van het solo cv toestel aan op de bovenste aansluiting
van het voorraadvat
Selecteer ARR 1 in de besturingsregeling Deltasol BS Plus
Sluit de 3wegklep aan volgens de voorschriften van het solo cv toestel
Controleer en stel de temperatuur in van het solo cv toestel op 65 graden
Figuur 8.1
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for HRSolar HRS500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of HRSolar HRS500 in the language / languages: Dutch as an attachment in your email.

The manual is 1,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info