Installation and Assistance
* Only available in selected models.
If the appliance must be moved at any time, keep it in an
upright position; if absolutely necessary, it may be tilted onto its
back.
Positioning and levelling
1.Removetheappliancefromall packaging andcheckthat
it has not been damaged during transportation. If it has been
damaged, contact the retailer and do not proceed any further
with the installation process.
2.Arrangethedishwashersothatitssidesorbackpanelarein
contactwiththeadjacentcabinetsorthewall.Thisappliance
can also be recessed under a single worktop*
(see the Assembly
Instruction sheet.)
3. Position the dishwasher on a level sturdy floor. If the floor
isuneven,thefrontfeetoftheapplianceshouldbeadjusted
untilitreachesahorizontalposition.Iftheapplianceislevelled
correctly, it will be more stable and much less likely to move or
cause vibrations and noise while it is operating.
4*.Toadjusttheheightoftherearfoot,turntheredhexagonal
bushing on the lower central part at the front of the dishwasher
using a hexagonal spanner with an opening of 8 mm. Turn the
spanner in a clockwise direction to increase the height and in an
anticlockwise direction to decrease it
(see Building-in Instruction
sheet attached to the documentation.)
Connecting the water and electricity supplies
Connection to the water and electricity supplies should only
beperformedbyaqualifiedtechnician.
The dishwasher should not stand on the water hoses or
electricity supply cable.
The appliance must be connected to the water supply
network using new hoses.
Do not use old piping.
The water inlet and outlet hoses and the electricity supply cable
may be positioned towards the right or the left in order to achieve
the best possible installation.
Connecting the water inlet hose
• Toasuitablecoldwaterconnectionpoint:beforeattaching
the hose, run the water until it is perfectly clear so that any
impurities that may be present in the water do not clog the
appliance; after performing this operation, screw the inlet
hose tightly onto a tap with a ¾ gas threaded connection.
• Toasuitablehotwaterconnectionpoint:yourdishwasher
may be supplied with hot water from the mains supply (if you
have a central heating system with radiators) provided that it
doesnotexceedatemperatureof60°C.
Screw the hose to the tap as described for connection to a
cold water supply.
If the inlet hose is not long enough, contact a specialist store
or an authorised technician
(see Assistance.)
The water pressure must be within the values indicated in
the Technical Data table
(seeadjacentinformation.)
The hose should not be bent or compressed.
Connecting the water outlet hose
Connect the outlet hose (without bending it) to a drain duct with
a minimum diameter of 4 cm.
Theoutlethosemustbeataheightrangingfrom40to80cm
fromthefloor/surfacewherethedishwasherrests(A).
Before connecting the water outlet hose to the sink drain, remove
the plastic plug (B).
Anti-flooding protection
To ensure floods do not occur, the dishwasher:
- is provided with a special system which blocks the water supply
in the event of anomalies or leaks from inside the appliance.
Somemodelsarealsoequippedwiththesupplementarysafety
device New Acqua Stop*, which guarantees anti-flooding
protection even in the event of a supply hose rupture.
WARNING: HAZARDOUS VOLTAGE!
Under no circumstances should the water inlet hose be cut, as
it contains live electrical parts.
Electrical connection
Before inserting the plug into the electrical socket, make sure
that:
• Thesocketisearthedandcomplieswithcurrentregulations.
• thesocketcanwithstandthemaximumloadoftheappliance,
which is indicated on the data plate located on the inside of
the door
(see Description of the appliance);
• Thepowersupplyvoltagefallswithinthevaluesindicatedon
the data plate on the inside of the door.
• Thesocketiscompatiblewiththeplugoftheappliance.If
this is not the case, ask an authorised technician to replace
the plug (
see Assistance
); do not use extension cables or
multiple sockets.
Once the appliance has been installed, the power supply
cable and the electrical socket should be easily accessible.
The cable should not be bent or compressed.
If the power supply cable is damaged, it must be replaced
by the manufacturer or its Technical Assistance Service in order
topreventallpotentialhazards
(see Assistance.)
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Hotpoint-Ariston LFK 7B019 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Hotpoint-Ariston LFK 7B019 in the language / languages: English, Italian as an attachment in your email.

The manual is 4,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info