Wiring
1.0 - 2.5 mm²
8 mm max.
Wiring diagrams
Test system and finish installation
• AllwiringmustbeinaccordancewithIEERegulations.Thisthermostatisforxedwiringonly.
• Aswitch,havingcontactseparationofatleast3mminallpolesmustbeincorporatedinthexedwiringasa
means of disconnecting the supply.
• ThethermostatisaClassII(doubleinsulated)device.Aparkingterminalisprovidedforexternalearthwiring
continuity.
• Theheatingsystemmustincorporateafuseratedatnomorethan10Amps.Thecoolingsystemmust
incorporate a fuse rated at no more than 6 Amps.
• Thethermostathas4knockoutsonthecovertoaccommodatesurfacewiring.Makesurethecablecompletely
fills the knockout hole without leaving any gaps. Where used, mini-trunking must be fitted firmly against the
thermostat cover in such a way as to leave no gap.
1 Replace cover and secure with
screw as shown at left.
2 Check the power supply to make
sure the heating system is on.
3 Turn the control dial to raise
targettemperatureto30°C.If
the thermostat is wired properly,
the heating system should begin
running.
4 To stop the test, turn the control
dial to lower the target temperature
to an appropriate level. The heating
system should turn off.
Turn dial to 30°C to test
Replace and secure cover
Connect wiring from your heating or cooling
equipment to the thermostat as shown at left.
See wiring diagrams for details.
1 Make sure electrical power is off.
2 Strip insulation to expose about 6 mm of
bare wire.
3 Use a screwdriver to loosen terminal screw,
insert wire into slot, then tighten screw.
4 See below to test and finish installation
NOTE: All wiring must comply with IEE
regulations. Keep AC mains supply/load cables
separate from equipment wiring.
Honeywell
The Arnold Centre
Paycocke Road
Basildon,Essex
SS143EA
TechnicalHelpDesk:08456042893 50051981-001Rev.A
www.homexpertbyhoneywell.com © 2010 Honeywell International Inc
homexpert
tm
by Honeywell is a trademark of Honeywell International Inc. All rights reserved.
Heating application Cooling application
Honeywell warrants this product for 1 year from date
of purchase. We undertake to replace or repair at our
discretion, products should they become defective
within 1 year solely as a result of faulty materials and or
workmanship.
Understandably if the product has not been installed or
maintained in accordance with Honeywell’s instructions,
has not been used appropriately or if any attempt has
been made to rectify, dismantle or alter the product in
any way the warranty will be invalidated.
This product warranty states Honeywell’s entire liability.
It does not extend to cover consequential loss or
damage or installation costs arising from a defective
product.
If the product is defective, please return it together with
a proof of purchase or receipt to the place of purchase.
This does not affect your statutory rights.
If you require further information about this product,
call the homexpert
tm
by Honeywell technical helpline on
08456042893.
For a full list of terms and conditions please visit
www.homexpertbyhonyewell.com.
Limited warranty
HEATING LOAD
COOLING LOAD
N
N
L
L
230v~
50-60 Hz
230v~
50-60 Hz
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell THR830TUK at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell THR830TUK in the language / languages: English as an attachment in your email.

The manual is 1,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info