Period Start Time Heat Setpoint Cool Setpoint Fan Setting
Sunday
Wake [6:00 AM] [70°F (21°C)] [78°F (25.5°C)] [Auto]
Leave [8:00 AM] [62°F (16.5°C)] [85°F (29.5°C)] [Auto]
Return [6:00 PM] [70°F (21°C)] [78°F (25.5°C)] [Auto]
Sleep [10:00 PM] [62°F (16.5°C)] [82°F (28°C)] [Auto]
Table 9. Default Time, Setpoints and Fan Settings (continued).
2. Press Day until the desired day is displayed.
M10318
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Day
Heat/Cool
Settings
Daylight
Time
Copy
Heat
Auto
System Fan
Wake
Mon
AM
Set Program
Start Time
Setting
Heat
3. Press Time or Time until the desired Wake time is
displayed.
NOTE: The program times are in fifteen minute
intervals. (Example: 8:00, 8:15, 8:30).
M10319
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Heat
Auto
System Fan
Wake
Mon
AM
Set Program
Start Time
Setting
Heat
Time
4. Press increase or decrease key until the desired
Wake temperature is displayed.
NOTE: The setpoint temperature range is 40 to 90°F
(7 to 31°C) for heating and 45 to 99°F (9 to
37°C) for cooling.
M10320
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Heat
Auto
System Fan
Wake
Mon
AM
Set Program
Start Time
Setting
Heat
NOTE: Press Fan to modify fan operation. Auto means
the fan will run only when the heating or
cooling equipment is operating. On means the
fan will run continuously for the entire period.
5. Press Heat/Cool Settings to switch to other system
temperature setpoint.
NOTE: The program times are the same for both
heating and cooling.
M10321
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Heat/Cool
Settings
Daylight
Time
Copy
Auto
System Fan
Wake
Mon
AM
Cool
Set Program
Start Time
Setting
Heat
6. Press increase or decrease key until the desired
temperature setpoint is displayed.
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Auto
System Fan
Wake
Mon
AM
Cool
Set Program
Start Time
Setting
Heat
M10322
7. Press Leave, Return or Sleep and repeat steps 3, 4, 5
and 5 for programming the rest of the day. The first day
is now programmed.
M10323
Time Set Program
System Fan
Run
Program
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Auto
System Fan
Wake
Room
AM
DST
Tue
Heat
Copying a Day
NOTE: The thermostat must be in the program mode to use
the copy feature. Go to step 2 if the thermostat is
already in the program mode.
1. Press Wake.
M10324
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Heat
Auto
System Fan
Wake
AM
Tue
Set Program
Start Time
Setting
Heat
IMPORTANT
Repeat steps
1
through
7
for each day of the week
that has a different program than the first day. Refer
to Copying a Day section to copy any program day to
another.
8. Press Run Program when all days are programmed.
2. Press Day to select the day to be copied if different
from the day displayed.
M10325
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Day
Heat/Cool
Settings
Daylight
Time
Copy
Heat
Auto
System Fan
Wake
Mon
AM
Set Program
Start Time
Setting
Heat
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell T8601D Chronotherm IV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell T8601D Chronotherm IV in the language / languages: English as an attachment in your email.

The manual is 0,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info