T8600D, T8601D AND T8602D CHRONOTHERM
®
IV DELUXE PROGRAMMABLE THERMOSTATS
68-0164—1
11
NOTE: Press any key and the numbers will change on the
display. Press Time to scroll backwards and Time
to scroll forward. The Run Program, Key will not
exit from this test. To exit, go to a different test and
press Run Program.
THERMOSTAT INFORMATION
1. Press the Time key to access the thermostat
information.
M4934
2. Press the increase key to display the production date
code. The first two large digits are the month and the
third digit is the last digit of the year (Example:
027=February 1997).
M10351
3. Press the increase key again to display the software
identification code. (Example: 02 = software ID code 2)
M4932A
4. Press the increase key again to display the software
revision number (Example: 001=Revision number 1).
M10229
5. Press the increase key again to display the EEPROM
identification code. (Example: 314 = EEPROM ID 314)
6. Press the Run Program key to exit the system test. The
M4933A
system test times out after five minutes without any key
presses.
PROGRAMMING
The keyboard is located behind the thermostat cover with
three frequently used keys by the display. The thermostat
display shows day, time, program period, temperature, system
and fan operation selection.
The thermostat can be set for four times and up to eight
temperatures for each day of the week (28 independent time
and 56 temperature settings). The and keys provide
quick temporary temperature changes to increase comfort.
The Hold Temp key provides energy efficient operation for
extended periods of time.
Before starting the programming procedure, use Table 9 to
organize the program schedule. The factory preprogrammed
time, temperature and fan settings are shown in brackets. If a
daytime energy savings period is not used, press the period
key (Leave or Return) until the time is blank. The fan setting
feature is available on select thermostat models.
Setting the Current Day and Time
IMPORTANT
Always press the keys with your fingertip or similar
blunt tool. Sharp instruments like pens and pencil
points can damage the keyboard.
1. Press Set Current Day/Time.
NOTE: On initial power up or after an extended power
loss, 1:00 pm flashes on the display until a key
is pressed.
M10312
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Heat/Cool
Settings
Daylight
Time
Copy
Mon
PM
Set Day/Time
2. Press Day until the current day is displayed.
NOTE: Sun = Sunday, Mon = Monday, Tue = Tuesday,
Wed = Wednesday, Thu = Thursday, Fri =
Friday, Sat = Saturday.
M10313
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Day
Heat/Cool
Settings
Daylight
Time
Copy
PM
Tue
Set Day/Time
3. Press Time or Time until the current time is
displayed.
NOTE: Tapping the Set Current Day/Time will change
the time in one hour increments.
M10314
Time Set Program
System Fan
Run
Program
Hold Temp
Set Current
Day/Time
Wake
Leave
Return Sleep
Day
Time
Heat/Cool
Settings
Daylight
Time
Copy
AM
Tue
Set Day/Time
11


Need help? Post your question in this forum.

Forumrules
1

Forum

honeywell-t8600d---chronotherm-iv

Reset search

  • The AC is not working. The repair person via a phone call said to turn off the system. How do I do this?
    I read the Manuel.
    The fuse is fine.
    Submitted on 28-7-2022 at 20:15

    Reply Report abuse
  • An HVAC repair person cannot come until next week. The AC is not working.
    He suggested I turn off the system. How do I do this? I read the manuel.
    It is not a problem with the fuse. Submitted on 28-7-2022 at 20:11

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell T8600D - Chronotherm IV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell T8600D - Chronotherm IV in the language / languages: English as an attachment in your email.

The manual is 0,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info