689549
2
Zoom out
Zoom in
Previous page
1/2
Next page
ParametersConfigure the System
3
Specific settings for the thermostat
and heating system can be
configured in the advanced menu.
Press and hold
and then
buttons together until the display
changes (approx. 3 seconds).
A) Press
and buttons to navigate
through the parameter list
B) Press
and buttons to
change a parameter
C) Press
button to save the change
(or press to cancel the change)
D) Press
button to exit advanced
menu and save any changes
N
o
Description Settings (default in bold)
1:LA
Language 1 = EN, 2 = NL, 3 = FR, 4 = DE, 5 = ES
2:CR
Heating Cycle Rate (cph) 3 (oil boiler / thermal actuator)
6 (gas or combi boiler / zone valve)
9
12
3:OT
Minimum on time 1 - 5 (mins) (set to 4 mins for oil boiler)
4:LL
Lower Temperature Limit 5 - 21 (°C)
5:UL
Upper Temperature Limit 21 - 35 (°C)
6:SO
Schedule options 1 = 7 day (different schedule each day of the week)
2 = 5 + 2 day (weekday + weekend schedule)
3 = 1 day (same schedule every day)
7:NP
Number of periods per day 4 or 6
8:SS
Wired Remote Sensor 0 = No Remote Sensor, 1 = Wired Remote Sensor
9:LC
Fail Safe mode 0 = Boiler off, 1 = Boiler 20% on / 80% off
10:BL
Backlight 0 = Off, 1 = On (only on demand)
11:CL
Clock Format 0 = 24 hr, 1 = AM/PM
12:DS
Daylight Saving time change 0 = Off, 1 = Auto
13:TO
Temperature Display Offset +/1.5°C
15:SD
Restore Schedule Defaults 0, 1 = reset
16:FS
Restore Factory Settings 0, 1 = reset
Parameter
Number
Parameter
Setting
Conforms to protection requirements of the following directives:
EMC: 2014/30/EU and LVD: 2014/35/EU
ErP: Class IV (+2%), (EU) 811/2013
WEEE Directive 2012/19/EC - Waste Electrical and Electronic Equipment directive
At the end of the product life dispose of the packaging and product in a corresponding recycling
centre. Do not dispose of the unit with the usual domestic refuse. Do not burn the product.
Troubleshooting
What’s happening? What it could mean... How to fix it...
Thermostat
display is blank
Batteries exhausted,
installed incorrectly or tab
hasn't been removed
Unclip thermostat from wall
and check battery installation -
replace batteries if necessary
Display =
Battery power critically low Unclip thermostat from wall and
replace batteries immediately
Display =
Faulty temperature sensor Replace thermostat or check wiring to
remote temperature sensor if fitted
Thermostat shows
heat demand
but boiler doesn't
respond
Boiler (water) already
at temperature
Normal behaviour - wait for
water temperature to drop
Faulty wiring connection Check wiring at thermostat
and boiler terminals
Manufactured for and on behalf of the Environmental & Energy Solutions
Division of Honeywell Technologies Sàrl, ACSE&ES, Z.A., La Pièce 16,
1180 Rolle, Switzerland by its Authorised Representative Honeywell Inc.
Honeywell Control Systems Ltd.
Skimped Hill Lane,
Bracknell,
Berkshire
RG12 1EB
www.honeywelluk.com
© 2016 Honeywell International Inc. | Printed in UK
Adding a Remote Temperature Sensor
A remote temperature sensor can be added
if the Thermostat needs to be installed in
a different location from where the room
temperature needs to be measured.
If a remote sensor is added parameter
N
o
8 Ss
needs to be changed to '1'.
Thermostat
T
T
S
S
A
B
C
12K
Polarity free
2


Need help? Post your question in this forum.

Forumrules
1

Forum

honeywell-t4

Reset search

  • How do I set a minimum temperature as it keeps coming on in the day time Submitted on 2-12-2022 at 14:28

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell T4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell T4 in the language / languages: English as an attachment in your email.

The manual is 0,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Honeywell T4

Honeywell T4 User Manual - English - 16 pages

Honeywell T4 User Manual - German - 16 pages

Honeywell T4 Installation Guide - German - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info