6
ENGLISH
OPERATING INSTRUCTIONS
A) MODELS HW-220E, HW-220F AND HW-221E
• Turn the thermostat anti-clockwise to its lowest
setting ().
• Plug in the panel heater.
• Turn the thermostat clockwise to the highest
temperature setting for rapid warming (fig.3).
• When the room reaches a comfortable tempera-
ture, turn the thermostat anti-clockwise until the
panel heater switches off. At this setting the thermo-
stat will automatically switch the panel heater on
(the pilot light comes on) and off (the pilot light
goes off) to maintain the selected temperature.
• To turn the panel heater off, turn the thermostat
anti-clockwise to the lowest setting (
) and unplug it.
B) MODELS HW-222E, HW-222F AND HW-223E
• Turn the switch to (0).
• Plug in the panel heater.
• Turn the switch to the desired power,
(I-Low, II-Medium, III-High) (fig.4).
• Turn the thermostat clockwise to its highest
setting for a rapid warming.
• When the room reaches a comfortable tempera-
ture, turn the thermostat anti-clockwise until the
panel heater switches off. At this setting, the ther-
mostat will automatically turn the panel heater on
(the pilot light illuminates) and off (the pilot light
goes out) to maintain the selected temperature.
• To turn the panel heater off, turn the switch to the
(0) position and unplug the panel heater.
TIMER OPERATION
C) MODEL HW-224TE, HW-224TF ONLY
• Follow the operating instructions under B) and
see Fig. 5 and 6.
• In order to operate the panel heater without using
the timer, place all timer pins in the “ON” position
(all pins close to the centre).
To set the timer:
• Put all “timer pins” close to the centre of the timer.
• Turn the dial clock until it corresponds to the
actual time of day.
• Each pin corresponds to a period of 20 minutes.
• To program the time desired to maintain the
heater off, place the number of pins desired away
from the centre of the timer.
• To program the time desired to maintain the
heater on, place the number of pins desired
close to the centre.
• Over a period of 24 hours, you can set any
number of switching periods by pulling out pins
For example see Fig. 6:
- Actual time: 9 p.m.
- Switches on at 9 p.m. and remains on for
2 hours.
- Remains off from 11 p.m. to 6 a.m.
- Switches on at 6 a.m. and remains on for
3 hours.
- Switches off at 9 a.m.
- Switches on at 9 p.m.
- Until changed, the program will repeat every
24 hours.
• To turn panel the heater off, turn the switch to the
(0) position and unplug it.
FROST PROTECTION
The panel heater is equipped with an anti-frost
function. Plug in the panel heater.Turn the switch
to I, II or III. Turn the thermostat anti-clockwise to its
lowest setting (). As soon as the room temperatu-
re is below + 6° C the panel heater will automatical-
ly switch on.
AUTOMATIC SAFETY CUT-OUT
This panel heater is equipped with an automatic
safety cut-out. If the panel heater stops unexpectedly,
the safety cut-out may have operated. Once the safety
cut has operated, the heater will not restart until the
panel heater has been turned off and cooled down. In
this situation, you are recommended to turn the switch
to the (0) position and unplug the panel heater. Allow
the panel heater to cool. Plug the panel heater into a
socket and follow the “Operating Instructions”.
IF THE PANEL HEATER FAILS
TO OPERATE
• Check for and remove any obstructions.
• Check if the panel heater is in the right position
and if it is plugged in. Check if the power socket
is working (e.g. plug in a different working
electrical device).
• Make sure that the thermostat is not set too low.
• With the switch set to one of the power settings
(I, II or III) turn the thermostat clockwise until the
heater restarts.