AUTOMATIC FUNCTIONS
WINDOW FUNCTION
If you open a window and the temperature drops sharply within a
short period, the radiator controller closes the radiator valve in
order to save energy. The display then shows the message .
When the temperature rises again, the radiator controller returns
to normal operation, however at the latest after 30 minutes.
The window function can be deactivated at the command centre.
PROTECTION AGAINST VALVE MALFUNCTION
If the valve is not opened once completely within a period of
2 weeks, the valve is opened and shut again briefly. This
ensures that the valve does not seize. The display then shows
the message cycle. The 2-week cycle begins at the moment
at which the operating unit is connected to the valve lantern.
FROST PROTECTION
If the temperature drops below 5 °C, the radiator controller
keeps the radiator valve at a constant 5 °C.
The frost-protection value (standard value: 5 °C) can be
changed at the command centre.
The frost-protection function does not function when the batteries
are empty or the operating unit is removed.
STATUS MESSAGE E3
If the symbol e3 is shown on the display, the motor of the HR 80
can no longer be moved.
SERVICE MODE (FOR INSTALLERS ONLY)
The wireless contact between the radiator controller, the
command centre and a receiver unit is checked in Service
mode.
Separate operating unit from coupling module (see Section
"Finishing installation of radiator controller").
Turn the adjustment dial until on (open) appears in the
display.
Turn adjustment dial two full rotations (720°) further.
TesT is displayed. Service mode is active.
The radiator controller transmits a test message to any avail-
able receiver unit (e.g. HC60ng).
Press the binding procedure button.
The radiator controller is ready to receive the test message
from the command centre.
The first two digits in the display indicate the number of re-
ceived test messages, and the right-hand digit indicates the
field strength (1 = sufficient field strength, 5 = very good field
strength)
To deactivate Service mode:
Press the binding procedure button for 5 seconds or wait
5 minutes or remove and then reinsert the batteries.
Service mode is deactivated.
DISPOSAL (WEEE DIRECTIVE 2002/96 EG)
At the end of the product life dispose of the packaging and
product in a corresponding recycling centre. Do not dispose of the
unit with the usual domestic refuse. Do not burn the product.
TECHNICAL DATA
Power consumption (standby) 0.15 mW
Power consumption (motor in action) 105 mW
Control accuracy 0.7 °C
Protection class IP30
Ambient temperature 0 °C ... +50 °C
Storage temperature –20 °C ... +70 °C
Humidity 5 … 95 % rel. humidity
Dimensions (L x W x H) 100 x 50 x 80 mm
Weight 220 g, with batteries
CE standards EN 61000-6-3
EN 61000-6-1
EN 300-220
EN 301-489
The radiator controller HR 80 is certified according to eu.bac.
Manufactured for and on behalf of the Environmental and Combustion
Controls Division of Honeywell Technologies Sàrl,
Rolle, Z.A.
La Pièce 16, Switzerland by its Authorized Representative:
Honeywell GmbH
Böblinger Straße 17
71101 Schönaich
http://europe.hbc.honeywell.com
The right is reserved to make modifications.
This document replaces all previous publications.
MU2H0349GE51 R1209E
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell HR 80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell HR 80 in the language / languages: English, German as an attachment in your email.

The manual is 0,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Honeywell HR 80

Honeywell HR 80 Installation Guide - Dutch - 44 pages

Honeywell HR 80 User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info