725701
17
Zoom out
Zoom in
Previous page
1/142
Next page
13EN
WATER CONDENSATION DRAINAGE
When there is excess water condensation inside the unit, the Local Air Conditioner stops running
and shows an error code "P1" with an alarm. This indicates that the water condensation needs to be
drained using the following procedures:
Unplug the unit from power source.
Place a shallow pan under the lower rubber drain plug.
See diagram.
Remove the drain plug cap.
Water will drain out and collect in the shallow pan.
After the water is drained, replace the drain plug cap.
You can now turn on the unit.
1.
2.
3.
4.
5.
6.
Water may need to be drained in high humidity areas.
Lower
Rubber
Drain Plug
Shallow Pan
(not included)
Manual Draining in Cooling, Dehumidifying and Auto Modes
Unplug the unit from power source.
Remove the upper drain plug cap.
Some residual water may spill so please have a pan to
collect the water.
Connect the drain tube (included) to the upper drain
plug. See diagram.
The water can be continuously drained through the
drain tube into a floor drain or bucket.
Replace the drain plug cap.
You can now turn on the unit.
1.
2.
3.
4.
5.
6.
Continuous Draining for Dehumidifier Mode
Drain Tube (included):
Dia. 0.6" (1.6 cm)
Length: 23.6" (60 cm)
Upper Rubber
Drain Plug
While using the unit in dehumidifier mode, continuous drainage is recommended.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell HF08CES at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell HF08CES in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 19,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info