723878
3
Zoom out
Zoom in
Previous page
1/21
Next page
3
SET UP
MOVING THE HEATER
The Honeywell Ceramic Tower Heater requires no assembly. Simply unpack heater and save all packaging materials for o-
season storage.
Place the heater on a rm, level, open surface free from obstructions and at least 3 feet (0.9m) away from any wall or
combustible material.
DO NOT use on an unstable surface such as bedding or deep carpeting.
BE SURE THE HEATER IS NOT IN A POSITION WHERE IT MAY BE TRIPPED OVER BY CHILDREN OR PETS.
This heater is equipped with a Cool Touch handle for your convenience.
Turn o the heater.
Allow it to cool for ten minutes.
Unplug heater and move.
OPERATION
NOTE: NEVER LEAVE AN OPERATING UNIT UNATTENDED
With heater in the OFF position ( ), plug the heater into
a polarized 120V outlet. DO NOT FORCE THE POLARIZED
PLUG INTO THE OUTLET; it will only t one way.
With 80° oscillation, the Honeywell Ceramic Tower Heater
is versatile and designed to be placed in the center of the
room or closer to the wall (at least 3 feet way) for maximum
convection room heating.
Turn heater on by pressing the Power Button ( ).The Power
Indicator will illuminate and the heater will start in the
Constant On HI Level Setting ( ).
The heater has two operational modes – continuous heating
or heating with a thermostat setting where the heater cycles
on and o according to the selected temperature setting.
To set a Continuous Heat Setting, press ( ): - Choose Low ( ) to use 900 watts of power (750 watts on the HCE317 Series only)
- Choose High ( ) to use 1500 watts of power
NOTE: Because the Low setting does not require as much electricity to operate, it is more energy ecient and may be a better
option if you are concerned about saving energy.
In the continuous heat mode, make sure to manually turn the heater OFF when done using this appliance.
To set the Thermostat, press the Thermostat Control Buttons ( ) and choose your Desired Temperature. The Desired
Temperature will ash ve times and then the Current Temperature in the room will display as a steady red. On the HCE305/HCE309
unit models only, there are 4 pre-set comfort settings from which to choose: 65°, 70°, 75°, 80°. These are your desired
room temperature settings.
NOTE: If the Current Temperature is higher than your Desired Temperature, the heater will be o until the room temperature falls
below this setting or until the Desired Temperature is changed.
Press the Timer Button ( ) to select 1, 2, 4, or 8 hour setting. The heater will run for that chosen period in the selected mode,
counting down the hours and automatically shutting the heater o after the selected time has passed.
If unit has an oscillation feature, press the Oscillate Button ( ) to turn on or o the oscillation function.
To shut the heater o, press the Power Button ( ) and the heater will begin Powering Down. The heater will shut o after counting
down 6 seconds in the Temperature Display to cool down the internal components.
It is important to allow the heater to run through the cool down phase. DO NOT unplug the heater until it has completed the cool
down cycle.
Oscillate Button
Fig. 1
Power
Button
Timer
Thermostat
Control Buttons
Current Temperature/
Desired Temperature Display
Heat Level Settings
Power
Indicator
Note: Controls/features will vary slightly by model
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell HCE322 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell HCE322 in the language / languages: English, French, Spanish as an attachment in your email.

The manual is 0,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info