613723
12
Zoom out
Zoom in
Previous page
1/32
Next page
Rev 1.01 4 900.0355
01/06
Dual Power Model (12 VDC / 24 VAC)
This model has an AC/DC compatible input terminal. Either a
12 VDC or 24 VAC power supply cable can be connected to
this terminal. The camera automatically detects the power
source.
Recommended wire gauge Solid wire: F 1.2 mm (AWG16),
Stranded wire: 0.25 mm (AWG16), Element wire: F 0.18 Min.
1. Connect the power cable to the AC/DC compatible input
terminal on the rear panel of the camera.
12 VDC: +12 VDC should connect to the red terminal, 0
VDC to the white terminal, black terminal for ground.
Figure 3 Dual Power Model
Note Ensure that the power cord is long enough that
it will not pull off the camera when the camera
pans or tilts.
Red = live, reference line lock.
White = neutral.
Black = ground.
Voltage range is 12 VAC ~ 28 VAC, 10 VDC ~
30 VDC.
Connecting the Video Cable
It is recommended to use a monitor whose resolution is at
least equal to the camera resolution.
1. Set the termination switch on the last monitor to the 75 Ω
position.
2. Set all other monitors to the Hi-Z position. Do not change
the positions after setting.
3. Use a 75 W coaxial cable. The maximum extensible
coaxial cable length between the camera and the monitor
is shown in the following table.
DC Auto Iris output
connector
BNC Video output
Video Auto Iris
output
RS485 controller
IR lamp contact
Terminal block
Power input
Power
Termination
resistor switch
(see Connecting
the RS485 Cable)
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell HCD484EX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell HCD484EX in the language / languages: English as an attachment in your email.

The manual is 0,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info