FocusPRO
®
6000
Series
Installation
Instructions
Programmable
Digital
Thermostat
M29433
Wallplate installation
Remove the wallplate from the thermostat,
then follow directions below for mounting.
1. Remove battery holder.
2. Pull here to remove wallplate from new
thermostat.
3. Pull wires through wire hole.
4. Position wallplate on wall, level and mark
hole positions with pencil.
5. Drill holes at marked positions as shown
below, then tap in supplied wall anchors.
6. Place wallplate over anchors, insert and
tighten mounting screws.
7. Insert reference card.
M29369
Drill 7/32"
holes for
plaster.
Drill 3/16"
holes for
drywall.
Wire hole
Mounting
screws
MCR29434
2
MCR29436
Power options
Wiring terminal designations
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
Keep wires in this
shaded
area
Connect C for primary AC power
(optional if batteries are installed).
Insert batteries for primary
or backup power.
Remove factory-
installed jumper
only for two-
transformer
systems.
Conventional Terminals:
Rc 24VAC power from cooling
transformer
R 24VAC power from heating
transformer
W Heat relay (stage 1)
W2 Heat relay (stage 2)
Y Compressor contactor (stage 1)
Y2 Compressor contactor (stage 2)
G Fan relay
C 24VAC common. For 2 transformer
systems, use common wire from
cooling transformer.
Heat Pump Terminals:
Rc 24VAC power from cooling
transformer
R 24VAC power from heating
transformer
O/B Changeover valve
Y Compressor contactor
Y2 Compressor contactor (stage 2)
-TH6320U only
G Fan relay
Aux/E Auxiliary/Emergency heat relay
L Sends output when set to Em. Heat
C 24VAC common
TH6110D
RcYWGRC
TH6220D
RcYWGW2Y2 RC
TH6320U
RcYWGW2Y2 RC
MCR29437A
TH6110D
RcYGRC
RcY
G
LR
C
TH6220D
RcYGAux
E
Y2
LR
C
TH6320U
MCR29438A
Aux
E
3
Wiring conventional systems
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
1H/1C System
(1 transformer)
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor
C 24VAC common [3]
W Heat relay
G Fan relay
Heat-only System
Rc Power [1]
R [R+Rc joined by jumper]
C 24VAC common [3]
W Heat relay
Heat-only System
(Series 20) [5]
Rc [R+Rc joined by jumper]
R Series 20 valve terminal “R” [1]
Y Series 20 valve terminal “W”
C 24VAC common [3]
W Series 20 valve terminal “B”
Heat-only System
(normally open zone
valve) [5]
Rc [R+Rc joined by jumper]
R Power [1]
Y Normally open zone valve
C 24VAC common [3]
1H/1C System
(2 transformers)
Rc Power (cooling transformer) [1, 2]
R Power (heating transformer) [1, 2]
Y Compressor contactor
C 24VAC common [3, 4]
W Heat relay
G Fan relay
Heat-only System
with Fan
Rc Power [1]
R [R+Rc joined by jumper]
C 24VAC common [3]
W Heat relay
G Fan relay
Cool-only System
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor
C 24VAC common [3]
G Fan relay
2H/2C System
(1 transformer) [6]
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor (stage 1)
C 24VAC common [3]
W Heat relay (stage 1)
G Fan relay
W2 Heat relay (stage 2)
Y2 Compressor contactor (stage 2)
2H/2C System
(2 transformers) [6]
Rc Power (cooling transformer) [1, 2]
R Power (heating transformer) [1, 2]
Y Compressor contactor (stage 1)
C 24VAC common [3, 4]
W Heat relay (stage 1)
G Fan relay
W2 Heat relay (stage 2)
Y2 Compressor contactor (stage 2)
RcYWGRC
M29372
RcYWRC
M29374
RcYRC
M29375
RcYWG RC
M29376
RcWG RC
M29377
RcYG RC
M29378
RcYWGW2Y2 RC
M29379
RcYWGW2Y2 RC
M29380
NOTES
Wire specifications:
Use 18- to 22-gauge thermostat wire.
Shielded cable is not required.
[1] Power supply. Provide disconnect means
and overload protection as required.
[2] Remove jumper for 2-transformer systems.
[3] Optional 24VAC common connection.
[4] Common connection must come from cool-
ing transformer.
[5] In Installer Setup, set system type to
Heat Only.
[6] In Installer Setup, set system type to
2Heat/2Cool Conventional.
[7] In Installer Setup, set changeover valve to
O or B.
[8] In Installer Setup, set system type to
2Heat/1Cool Heat Pump.
[9] In Installer Setup, set system type to
2Heat/2Cool Heat Pump.
[10] In Installer Setup, set system type to
3Heat/2Cool Heat Pump.
[11] L terminal sends a continuous output when
thermostat is set to Em. Heat. Connect
to Honeywell zoning panels to switch the
panel to Emergency Heat.
4
MCR29453
Thermostat mounting
1. Push excess wire back into the
wall opening.
2. Plug wall opening with non-
flammable insulation.
3. Align the 4 tabs on the wallplate
with corresponding slots on the
back of the thermostat.
4. Push gently until the thermostat
snaps in place.
1H/1C Heat Pump
System
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor
C 24VAC common [3]
O/B Changeover valve [7]
G Fan relay
2H/1C Heat Pump
System (TH6220D
only) [8]
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor
C 24VAC common [3]
O/B Changeover valve [7]
G Fan relay
Aux/E Auxiliary/Emergency heat relay
L Sends output when set to Em. Heat [11]
2H/1C Heat Pump
System (TH6320U
only) [8]
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor
C 24VAC common [3]
O/B Changeover valve [7]
G Fan relay
Aux/E Auxiliary/Emergency heat relay
L Sends output when set to Em. Heat [11]
2H/2C Heat Pump
System (TH6320U
only) [9]
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor (stage 1)
C 24VAC common [3]
O/B Changeover valve [7]
G Fan relay
Y2 Compressor contactor (stage 2)
L Sends output when set to Em. Heat [11]
3H/2C Heat Pump
System (TH6320U
only) [10]
Rc Power [1]
R [R+Rc joined by jumper]
Y Compressor contactor (stage 1)
C 24VAC common [3]
O/B Changeover valve [7]
G Fan relay
Aux/E Auxiliary/Emergency heat relay
Y2 Compressor contactor (stage 2)
L Sends output when set to Em. Heat [11]
See Notes on page 3.
Rc
YGAux
E
LR
C
Rc
YGAux
E
LR
C
Rc
YGY2
LR
C
Rc
YGAux
E
LR
C
Y2
Wiring heat pump systems
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
Rc
Y
GR
C
M29381
5
1
0
Done Next
MCR29454
1
0
Done Next
MCR29454
Follow the procedure below to configure
the thermostat to match the installed
heating/cooling system, and customize
feature operation as desired.
1. To begin, press and hold the
s
and FAN buttons until the display
changes.
2. Press
s or t to change settings.
3. Press NEXT to advance to next
function.
4. Press DONE to exit and save
settings.
Installer setup
Setup function Settings & options (factory default in bold)
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
1 System type
0 1 heat/1 cool conventional
1 1 heat/1 cool heat pump (no aux. heat)
2 Heat only — 2-wire systems, 3-wire zone valves (Series 20),
and normally open zone valves
3 Heat only with fan
4 Cool only
5 2 heat/1 cool heat pump (with aux. heat)
6 2 heat/2 cool conventional
7 2 heat/1 cool conventional
8 1 heat/2 cool conventional
9 2 heat/2 cool heat pump (no aux. heat) - TH6320U only
10 3 heat/2 cool heat pump (with aux. heat) - TH6320U only
2 Changeover valve
(O/B terminal)
0 Changeover valve (O/B terminal energized in cooling)
1 Changeover valve (O/B terminal energized in heating)
3 Fan control
(heating)
0 Gas or oil furnace — equipment controls fan in heating
1 Electric furnace — thermostat controls fan in heating
5 Stage 1 heat cycle
rate
(CPH: cycles/hour)*
5 For gas or oil furnaces of less than 90% efficiency
1 For steam or gravity systems
3 For hot water systems & furnaces of over 90% efficiency
9 For electric furnaces
6 Stage 2 heat cycle
rate/Auxiliary heat
cycle rate (CPH)*
5 For gas or oil furnaces of less than 90% efficiency
1 For steam or gravity systems
3 For hot water systems & furnaces of over 90% efficiency
9 For electric furnaces
7 Auxiliary heat
cycle rate (CPH)*
Only TH6320U
for 3H/2C Heat
Pumps
5 For gas or oil furnaces of less than 90% efficiency
1 For steam or gravity systems
3 For hot water systems & furnaces of over 90% efficiency
9 For electric furnaces
Function
number
Setting
*[Other cycle rate options: 2, 4, 6, 7, 8, 10, 11 or 12 CPH]
6
9 Stage 1 compressor
cycle rate (CPH)
3 Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
10 Stage 2 compressor
cycle rate (CPH)
3 Recommended for most compressors
[Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
12 Manual/Auto
changeover
0 Manual changeover (Heat/Cool/Off)
1 Auto changeover (Heat/Cool/Auto/Off)
2 Auto changeover only (Auto)
13 Adaptive Intelligent
Recovery™
1 On**See page 8
0 Off
14 Temperature
display
0 Fahrenheit
1 Celsius
15 Compressor
protection
5 Five-minute compressor off time
[Other options: 0, 1, 2, 3 or 4-minute off time]
16 Schedule format
0 5/2 (programmable weekdays and weekends)
1 5/1/1 (weekdays, Saturday & Sunday programmable)
26 Auxiliary heat
control
0 Comfort
1 Economy
27 Heat temperature
range stops
90 Max. heat temperature setting is 90 °F (32 °C)
[Other options: 40 °F to 89 °F (4.5 °C to 31.5 °C)]
28 Cool temperature
range stops
50 Min. cool temperature setting is 50 °F (10 °C)
[Other options: 51 °F to 99 °F (10.5 °C to 37 °C)]
Setup function Settings & options (factory default in bold)
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
Special function
Auto Changeover (Setup Function 12): When set to Auto, the thermostat
automatically selects heating or cooling depending on the indoor temperature.
The thermostat will automatically adjust heat and cool settings to maintain
a 3-degree separation (fixed). Note: If you select Auto Changeover Only,
the System Setting on the thermostat will stay locked in the Auto position,
preventing the user from changing it to Em Heat, Heat, Cool or Off.
Adaptive Intelligent Recovery (Setup Function 13): Allows the thermostat
to “learn” how long the furnace and air conditioner take to reach programmed
temperature settings, so the temperature is reached at the scheduled time.
Compressor Protection (Setup Function 15): Forces the compressor to wait
a few minutes before restarting, to prevent damage. During the wait time, the
message Cool On or Heat On (heat pumps only) will flash on the display.
7
10
0
MCR2945
5
10
0
MCR29455
Installer system test
1. To begin, press and hold the
s and t buttons until the
display changes.
2. Press s / t to turn system
on/off.
3. Press NEXT to advance to next
test
4. Press DONE to terminate
system test.
Temperature Ranges
Heat: 40° to 90°F (4.5° to 32°C)
Cool: 50° to 99°F (10° to 37°C)
Operating Ambient Temperature
32° to 120°F (0° to 48.9°C)
Shipping Temperature
-20° to 120°F (-28.9° to 48.9°C)
Operating Relative Humidity
5% to 90% (non-condensing)
Physical Dimensions
3-9/16” H x 5-13/16” W x 1-1/2” D
91 mm H x 147 mm W x 38 mm D
Electrical Ratings
Terminal Voltage (50/60Hz) Running Current
W Heating 20-30 Vac 0.02-1.0 A
(Powerpile) 750 mV DC 100 mA DC
W2 (Aux/E) Heating 20-30 Vac 0.02-1.0 A
Y Cooling 20-30 Vac 0.02-1.0 A
Y2 Cooling 20-30 Vac 0.02-1.0 A
G Fan 20-30 Vac 0.02-0.5 A
O/B Changeover 20-30 Vac 0.02-0.5 A
L Output 20-30 Vac 0.02-0.5 A
Specifications
System test System status
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
10 Heating system
0 Heat and fan turn off.
1 Stage 1 heat turns on. Fan turns on if Setup Function 1 is
set to 1, 5, 9 or 10 OR Setup Function 3 is set to 1
2 Stage 2 heat turns on
3 Stage 3 heat turns on - TH6320U only
20 Emergency heating
system
0 Heat and fan turn off
1 Heat and fan turn on
30 Cooling system
0 Compressor and fan turn off
1 Compressor and fan turn on
2 Stage 2 compressor turns on
40 Fan system
0 Fan turns off
1 Fan turns on
System test
number
System
status
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
Honeywell Ltd
705 Montrichard Avenue
Saint-Jean-sur-Richelieu, Québec
J2X 5K8
customer.honeywell.com
® U.S. Registered Trademark.
© 2014 Honeywell International Inc.
69-2695EFS05 M.S. Rev. 03-14
Printed in U.S.A.
69-2695EFS-05
For assistance with this product, please
visit customer.honeywell.com.
Or call Honeywell Customer Care toll-
free at 1-800-468-1502.
Customer assistance
Turn thermostat
over to find model
number and date
code.
Pull at bottom
to remove
thermostat
from
wallplate.
CAUTION:
EQUIPMENT DAMAGE HAZARD
Compressor protection is bypassed during testing. To prevent equipment damage, avoid
cycling the compressor quickly.
CAUTION:
ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before beginning
installation.
CAUTION:
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not
place the old control in the trash. Contact your local waste management authority for
instructions regarding recycling and proper disposal.
FocusPRO
®
6000 Série
Thermostat
numérique
programmable
Notice
D’installation
M29433
M29369
Installation de la plaque murale
Séparer la plaque murale du thermostat
comme, puis suivre les directives
d’installation.
1. Retirer le porte-pile.
2. Tirer ici pour enlever la plaque murale du
thermostat neuf.
3. Faire passer les fils par l’ouverture
réservée aux fils.
4. Placer la plaque murale sur le mur,
mettre de niveau et marquer au crayon
l’emplacement des trous.
5. Percer les trous aux endroits marqués à
l’aide d’une perceuse, puis insérer les
chevilles d’ancrage fournies.
6. Apposer la plaque murale sur les
chevilles, insérer puis resserrer les vis de
fixation.
7. Insérer la carte de référence.
Trou du fil
Vis de montage
Utiliser une
mèche de
3/16 po si le
mur est en
placoplâtre
Utiliser une mèche
de 7/32 po si le
mur est en plâtre.
MCR29434
2
MCR29436
Options d’alimentation
Désignation des bornes
Les zones ombragées ci-dessous s’appliquent seulement au TH6320U/
TH6220D ou selon les indications.
Garder les fils dans
cettezone
ombragée
Brancher C pour l’alimentation
CA primaire (facultatif si des piles
sont installées).
Insérer les piles pour l’alimentation
primaire ou de secours.
Enlever le cavalier
installé en usine
uniquement pour
les systèmes
à deux
transformateurs.
Bornes traditionnelles :
Rc Alimentation de 24 V CA pour
le transformateur de climatisation
R Alimentation de 24 V CA pour
le transformateur de chauffage
W Relais de chauffage (stade 1)
W2 Relais de chauffage (stade 2)
Y Contacteur du compresseur (stade 1)
Y2 Contacteur du compresseur (stade 2)
G Relais de la soufflante
C Neutre 24 V CA Pour les systèmes
à 2 transformateurs, utiliser le neutre
pour le transformateur de climatisation
Bornes de thermopompe :
Rc Alimentation de 24 V CA pour
le transformateur de climatisation
R Alimentation de 24 V CA pour
le transformateur de chauffage
O/B Robinet de substitution
Y Contacteur de compresseur
Y2 Contacteur du compresseur (stade 2)
-TH6320U seulement
G Relais de la soufflante
Aux/E Relais auxiliaire de chauffage/
de chauffage d’urgence
L Envoie le signal de sortie lorsque réglé
à Em. Chauffage
C Neutre 24 V CA
TH6110D
RcYWGRC
TH6220
D
RcYWGW2Y2 RC
TH6320
U
RcYWGW2Y2 RC
MCR29437A
TH6110D
RcYGRC
RcY
G
LR
C
TH6220D
RcYGAux
E
Y2
LR
C
TH6320U
MCR29438A
Aux
E
3
Guide de câblage – systèmes traditionnels
Les zones ombragées ci-dessous s’appliquent seulement au TH6320U/
TH6220D ou selon les indications.
Système 1C/1F
(1 transformateur)
Rc Alimentation [1]
R [R+Rc relié par le cavalier]
Y Contacteur de compresseur
C Neutre 24 V CA [3]
W Relais de chauffage
G Relais de la soufflante
Système de chauffage
seulement
Rc Alimentation [1]
R [R+Rc relié par le cavalier]
C Neutre 24 V CA [3]
W Relais de chauffage
Système de chauffage
seulement (Série 20) [5]
Rc [R+Rc reliés par le cavalier]
R Borne de soupape « R » de Série 20 [1]
Y Borne de soupape « W » de Série 20
C Neutre 24 V CA [3]
W Borne de soupape « B » de Série 20
Système de chauffage
seulement (soupape de
zone normalement ouverte) [5]
Rc [R+Rc reliés par le cavalier]
R Alimentation [1]
Y Soupape de zone normalement ouverte
C Neutre 24 V CA [3]
Système 1C/1F
(2 transformateurs)
Rc Alimentation (transformateur de
climatisation) [1, 2]
R Alimentation (transformateur de
chauffage) [1, 2]
Y Contacteur de compresseur
C Neutre 24 V CA [3, 4]
W Relais de chauffage
G Relais de la soufflante
Système de
chauffage seulement
avec soufflante
Rc Alimentation [1]
R [R+Rc reliés par le cavalier]
C Neutre 24 V CA [3]
W Relais de chauffage
G Relais de la soufflante
Système de
climatisation
seulement
Rc Alimentation [1]
R [R+Rc reliés par le cavalier]
Y Contacteur de compresseur
C Neutre 24 V CA [3]
G Relais de la soufflante
Système 2C/2F
(1 transformateur) [6]
Rc Alimentation [1]
R [R+Rc reliés par le cavalier]
Y Contacteur du compresseur (stade 1)
C Neutre 24 V CA [3]
W Relais de chauffage (stade 1)
G Relais de la soufflante
W2 Relais de chauffage (stade 2)
Y2 Contacteur du compresseur (stade 2)
Système 2C/2F
(2 transformateurs) [6]
Rc Alimentation (transformateur de
climatisation) [1, 2]
R Alimentation (transformateur de
chauffage) [1, 2]
Y Contacteur du compresseur (stade 1)
C Neutre 24 V CA [3, 4]
W Relais de chauffage (stade 1)
G Relais de la soufflante
W2 Relais de chauffage (stade 2)
Y2 Contacteur du compresseur (stade 2)
RcYWGRC
M29372
RcWRC
M29373
RcYWRC
M29374
RcYRC
M29375
RcYWG RC
M29376
RcWG RC
M29377
RcYG RC
M29378
RcYWGW2Y2 RC
M29379
RcYWGW2Y2 RC
M29380
REMARQUES
Spécifications des fils :
Utiliser du fil pour thermostat de calibre 18 à 22. Il
n’est pas nécessaire d’utiliser des câbles blindés.
[1] Alimentation. Procure un moyen de débrancher
et une protection contre la surcharge au besoin.
[2] Retirer le cavalier pour les systèmes à 2
transformateurs.
[3] Connexion facultative au neutre 24 V CA.
[4] La connexion du neutre doit venir du
transformateur de climatisation.
[5] Lors de la configuration, régler le type de
système à Chauffage seulement (Heat Only).
[6] Lors de la configuration, régler le type
de système à Traditionnel 2 chauffages/2
climatisations (2Heat/2Cool Conventional).
[7] Lors de la configuration, régler le type de
système à O ou à B.
[8] Lors de la configuration, régler le type de
système à Thermopompe 2 chauffages/1
climatisation (2Heat/1Cool Heat Pump).
[9] Lors de la configuration, régler le type de
système à Thermopompe 2 chauffages/2
climatisation (2Heat/2Cool Heat Pump).
[10] Lors de la configuration, régler le type de
système à Thermopompe 3 chauffages/2
climatisation (3Heat/2Cool Heat Pump).
[11] La borne L envoie un signal continu lorsque le
thermostat est réglé à Em. Chauffage Brancher
aux panneaux de zones Honeywell pour
commuter le panneau au chauffage d’urgence.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell FocusPRO TH6320U at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell FocusPRO TH6320U in the language / languages: English as an attachment in your email.

The manual is 3,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Honeywell FocusPRO TH6320U

Honeywell FocusPRO TH6320U User Manual - French, Spanish - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info