681056
2
Zoom out
Zoom in
Previous page
1/10
Next page
getconnected.honeywell.com
FG8MS
English
1 SELECT MOUNTING LOCATION
Refer to A (on page 1) and the following list for mounting guidelines.
Mount the detector between the protected glass and any heavy
window coverings that may be present. When heavy window coverings
are present, the detector can be mounted on the frame of the window
Do NOT mount the detector:
on posts or pillars
in rooms with noisy equipment (air compressors, power tools, etc.),
if this equipment is operated when the detector is armed
where the detector’s view of the glass may be obstructed
unintentionally
2 CONNECT THE BATTERIES (SEE B ON PAGE 1)
3 SELECT PROTOCOL (SEE B ON PAGE 1)
evohome=ALPHA
4 SET THE RANGE (SEE B ON PAGE 1)
For best false alarm immunity, measure distance from the intended
mounting location of the detector to the farthest point of glass to be
protected. The maximum distance should be 7.6 m. Set the shortest
range available with DIP switches SENS 1 and SENS 2 that is greater
than or equal to measured distance.
5 MOUNT THE DETECTOR
Orient the microphone for the best line-of-sight to the protected glass.
If ceiling mounted the end with the microphone should face the
protected glass.
Important: Not suitable for use on acoustic ceiling tiles if the rear
tamper will be used. Use drywall anchors if not mounting to a wall stud
or ceilin joist. If the rear tamper is used, tamper screw should screw
into frame, or a heavy-duty anchor, because the rear tamper requires
high breakawa force. Reinstall the battery (if removed for rear tamper
installation), then close and secure the detector front cover.
6 TEST MODES
TRANSMITTER Test Mode: This test mode shows transmitter activity.
It activates upon power-up and when the cover is opened. It remains
active for 10 minutes after the tamper switch is closed.
GLASSBREAK Test Mode: This test mode allows testing of the
glassbreak function. It is activated three ways – upon power-up,
by pressing the glassbreak test switch (see B on page 1).
For both test modes, refer to the following LED Indicators table.
LED INDICATORS (LEDs are only visible in test mode.)
CONDITION RED LED GREEN LED
Power Up ON 1 second ON 1 second
TRANSMITTER test mode
(10 minutes)
Flashes Briefl y
Once = ALPHA
Flashes Briefl y
Twice = V2GY
OFF
GLASSBREAK
test mode
(5 minutes
1
)
Normal OFF Flashes once per
second
and Flickers
when sound
detected
Alarm ON 5 seconds
Low
battery
2
Flashes once per
second
Normal Operation (Not in
test modes)
OFF OFF
1
5 minutes after the last sound that causes the green LED to fl icker.
2
When registered, the FG8MS sends a low battery signal to the pane
when the battery voltage gets low. Replace the battery. The detecto low
battery indication is approximate only.
7 TESTING GLASSBREAK WITHOUT AN FG-701 TESTER
Enter GLASSBREAK test mode. The Green LED will fl ash at 1Hz. Clap
hands near the detector and the Green LED will fl icker, verifying the
detector is hearing room noise. To test that that the panel is detecting
an alarm, tap on the detector cover with a fi nger nail or screwdriver until
the Red LED turns on for 5 seconds.
8 REGISTERING THE DETECTOR
1.
https://international.mytotalconnectcomfort.com
2.
Open and close the front cover.
3.
https://international.mytotalconnectcomfort.com
9 INSTALL COVER SCREW, IF REQUIRED
To secure the front cover after installation, remove the cover breakou
ash and secure the front cover with a 2.9 mm x 6.0 mm screw (no
provided.) Refer to D on page 1.
10 SPECIFICATIONS
Protected Glass Types:
NOTE: Minimum size for all types is 28cm x 28 cm.
Glass Type* Nominal Thickness
Minimum Maximum
Plate 2mm 10mm
Tempered 3mm 10mm
Laminated
1, 3
3mm 14mm
Wired 6mm 6mm
Coated
2, 3
3mm 6mm
Sealed insulating
1, 3
3mm [13mm overall] 6mm [19mm overall]
* Glass must be framed in the wall or mounted in a barrier at least 0.9m
wide.
1
Protected only if all plates or panes are broken.
2
Coated glass with security fi lms up to 0.35mm (14 mils) thick (including
lms for solar protection) may be used. Evaluated with the these
products: 3M® SCOTCHSHIELD® SH14CLARL – 0.35mm (14 mils), 4 ply
lm; Film Technologies International, Inc.’s GLASS-GARD GGLL 1200.
3
For these glass types, mounting at less than ½ the indicated range
setting is recommended. (Example: set SENS 1 and SENS 2 for 4.6 m
range, but mount the detector 2.3 m or less from the farthest glass to be
protected.)
FG8MS Wireless Glassbreak Detector –
Installation Instructions
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell FG8MS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell FG8MS in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 0,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info