522745
2
Zoom out
Zoom in
Previous page
1/8
Next page
CT54 THERMOSTAT
69-1696EF 2
MERCURY NOTICE
If this thermostat is replacing a control that
contains mercury in a sealed tube, do not place
the old thermostat in the trash. Contact your local
waste management authority for instructions
regarding recycling and proper disposal of this
control or of an old control containing mercury in
a sealed tube.
STEP 3. CONNECT WIRES TO NEW
THERMOSTAT
IMPORTANT
All wiring must comply with local building codes
and ordinances. If you are unsure about house-
hold wiring procedures, please call your local
heating/cooling contractor.
1. Remove the cover on the new thermostat. To
remove the cover, insert your thumb into the inden-
tation on the bottom and pull the cover away from
the thermostat (see Fig. 3).
2. Loosen the R and W terminal screws on the back
of the new thermostat (see Fig. 4).
3. Remove the two wires from the pencil and attach
one wire to the R terminal and the other wire to the
W terminal (see Fig. 4 and 5).
4. Plug the hole in the wall with insulation to prevent a
warm or cool draft from affecting the operation of
the thermostat.
Fig. 3. Remove cover on new thermostat.
Fig. 4. R and W terminals on new thermostat.
Fig. 5. Wraparound and straight wiring connections.
STEP 4. MOUNT NEW
THERMOSTAT TO WALL
1.
Position the thermostat on the wall.
Place a level
on top of the thermostat and use a pencil to mark
the two mounting holes on the wall (see Fig. 6).
2. Move the thermostat to the side and drill the
mounting holes in the wall using a 1/16 in. drill bit
at the locations you marked.
3. Position the thermostat over the drilled holes and
loosely insert the mounting screws into the drilled
holes. Check the leveling of the thermostat and
tighten the mounting screws. Do not over tighten.
Fig. 6. Mount new thermostat to wall.
M1964
6
BOTTOM OF
THERMOSTAT
COVER
M1964
7
R
W
M19648
F
OR WRAPAROUND
I
NSERTION STRIP
7
/16 IN. (11 MM)
FOR STRAIGH
T
INSERTION
STRIP
5/16 IN. (8 MM
)
.18
.2
.25
.3
.9
.7
.5
.4
L
O
N
G
E
R
LEVEL
DATE CODE
MODEL NO.
M19649
NOTE: MOVE TEMPERATURE
LEVER IF IT BLOCKS
MOUNTING HOLE
MOUNTIN
G
HOLE
MOUNTING
HOLE
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell CT54 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell CT54 in the language / languages: English, French as an attachment in your email.

The manual is 0,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info