7 69-0733—3
IMPORTANT:
Although the thermostat has a
low battery indicator, replace the batteries
once a year to prevent leakage and to prevent
the thermostat and heating/cooling system
from shutting down due to lack of battery
power.
As a precaution when leaving home for longer
than a month, change batteries before you leave
to prevent system from shutting down due to lack
of battery power.
Use fresh alkaline batteries; nonalkaline bat-
teries do not last as long, and may leak, causing
damage to the thermostat or the wall surface.
We recommend Energizer
®
batteries.
Adaptive Intelligent Recovery™
Selection
Before you program your thermostat, you must
decide if you want to leave the thermostat at
the factory-set Adaptive Intelligent Recovery™
setting, or adjust it to conventional recovery. If
you choose conventional recovery, adjust screw
3A (on the back of the thermostat) by turning
out
one turn.
With Adaptive Intelligent Recovery™, your home
gradually reaches the comfort temperature you
set at the exact time programmed into the ther-
mostat to achieve maximum energy savings and
comfort.
8 69-0733—3
More about Adaptive Intelligent Recovery™…
for the thermostat to adjust to the weather, your
lifestyle, home construction and heating/cooling
system.
With conventional recovery, the programmed time
marks the start of the time your furnace or air
conditioner comes on to start recovery; therefore,
you should program the start time to be earlier
than the desired comfort time. The best starting
time varies as the seasons change, but 30
minutes is a good head start time to use.
NOTE: If you adjust screw
3A for conventional re-
covery, a indicator
appears in the lower
right corner of the ther-
mostat display as a re-
minder that you are no longer using the Adap-
tive Intelligent Recovery™ feature.
PM
SET
PT
TUE
DAYTIME
INDICATES 
THERMOSTAT IS SET FOR 
CONVENTIONAL RECOVERY
M2483
This thermostat is actually a small but powerful
computer. When calculating the exact time to turn
on your furnace or air conditioner, it considers: (1)
air temperature, (2) the temperature of
the wall and (3) when you want the comfort
temperature established.
During recovery, the thermostat increases the
control temperature gradually and turns the equip-
ment on and off several times
before
reaching
your comfort time to save energy by avoiding
overshooting the comfort temperature. You can
see the current control temperature anytime dur-
ing recovery by pressing the CURRENT SET-
TING key.
This smart control learns from experience. Each
day it checks how closely it hit the target and
adjusts the recovery start time accordingly. It
normally takes
four to eight days after installation
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell CT3455 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell CT3455 in the language / languages: English as an attachment in your email.

The manual is 0,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info