CT3451 PROGRAMMABLE THERMOSTAT
7 69-1620—1
Press the key. Current configuration (CC) is
displayed. A typical example is shown, but CC
varies by model. (This information is for factory
use only.)
Exit Installer Setup.
Press the key to save all changes and return to
normal operation.
a
High efficiency furnace (90+).
b
Refer to the equipment manufacturer’s instructions.
9 PROGRAM YOUR THERMOSTAT
The thermostat is preprogrammed for your convenience
with the following time and temperature settings; see
Table 3. See energy saving charts at the end of this
document for energy-saving information.
Wake is the time period when you want the house at a
comfortable temperature when you get up in the morning.
NOTE: The heating and cooling program times are the
same. Changing your cooling Wake time also
changes your heating Wake time.
Leave is the time period you can set for an energy saving
temperature while you are away from home during the
day.
Return is the time period when you want the house at a
comfortable temperature when you come home during
the day.
Sleep is the time period when you can set an energy-
saving temperature while you are sleeping.
IMPORTANT
Always press the keys with your fingertip or sim-
ilar blunt tool. Sharp instruments like pens and
pencil points can damage the keyboard.
Setting Current Time and Day
1. To set current time, press Select twice. Press
or key to set current time.
NOTE: While setting the current time, the word SET is
displayed.
2. To set day of week, press Select again. Press
or key to set current day.
To use the preprogrammed time and temperature
settings (see Table 3), press Hold to exit the
programming mode.
Setting Weekday Program
Slide the System switch to the position, Heat or Cool,
that you want to program. A flame (heating) or a
snowflake (cooling) appears in the right side of the
display, when setting the program temperature.
1. Wake
a. Press Select. Press or key to set Wake
time.
b. Press Select. Press or key to set Wake
temperature.
Table 2. Heating Cycle Rate.
System Cycle Per Hr
Steam, gravity 1
Hydronic heat, condensing gas
furnaces
a
3
Gas or oil forced air (default) 6
Electric heat 9
Special applications 4, 5, 12
Table 3. Preprogrammed Time
and Temperature Settings.
Period Time
Heat
Setpoint
Cool
Setpoint
Wake 6:00 AM 70°F (21°C) 78°F (26°C)
Leave 8:00 AM 62°F (17°C) 85°F (29°C)
Return 6:00 PM 70°F (21°C) 78°F (26°C)
Sleep 10:00 PM 62°F (17°C) 82°F (28°C)
M1469
2
M12590A
PM
M12591
A
SET
PM
M1853
4
SET
M1857
0
SET
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell CT3451 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell CT3451 in the language / languages: English as an attachment in your email.

The manual is 0,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Honeywell CT3451

Honeywell CT3451 User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info