8 CM700 Wireless - Programmable Room Thermostat
4.3 Using the Room Thermostat for Specific Applications
The CM727/721 RF room thermostat is a versatile controller that can be used to control many different
applications. For most typical applications, like wall-hung gas fired combination boiler control or zone
valve control, no adjustments from the factory settings are required. For other applications, like controlling
an oil burner, the best system performance can be achieved by modifying selected parameters of the
room thermostat in the Installer mode. The table below lists the most common settings used for specific
applications.
4.4 Using the Special Features of the Room Thermostat
Special Feature: Description: Enable/Disable
Optimisation
(Variable Start Time)
The thermostat will adjust the start time in the morning/afternoon
so the desired temperature is reached by the start of the program
period. The system will restrict the start time to a max of 2 hours.
To enable: Set parameter
8:OP (category 1) to 1.
Scheduled
Maintenance Alert
Period
If the installation requires scheduled maintenance and the user
needs to be reminded that the service is due the parameter value
can be set to the required number of months (1-48). When the
preset period expires the CM721/CM727 will display the ‘SERVICE
icon.
Set parameter 19:SP
to the required value to
enable maintenance alert.
Value set to zero disables
the function.
Summer/Winter Auto
time change
This feature moves time automatically on the last Sunday of March
and the last Sunday of October. The feature is factory enabled.
To enable: Set parameter
3:tC (category 1) to 1.
Temperature Offset If the thermostat is located in a particularly hot/cold location
for reliable signal transmission reasons then the measured/
displayed temperature can be adjusted by +/- 3°C. This is useful
if the homeowner wants the reading to match another appliance
temperature display.
Set parameter 12:
tO (category 1) to the
required offset value.
Upper/Lower
Temperature Limit
The normal upper temperature limit of 35°C can be reduced to
21°C to save the homeowner energy. The normal lower limit of 5°C
can be increased up to 21°C to protect inhabitants from cold.
Set parameter 6:uL
(category 1) to the desired
upper limit.
Set parameter 7:LL
(category 1) to the desired
lower limit.
Specific Application: Setting: What to change:
Cycle/
Hour
Minimum
ON Time
Note: All parameters listed below belong to
category 2 - System Parameters (see Installer
Parameters Table)
HEATING
Gas Boiler
(<30kW)
6 1 No changes required
Oil Boiler 3 4 Set 1:Ot parameter to 4
Set 2:Cr parameter to 3
Thermal Actuator 12 1 Set 2:Cr parameter to 12
Zone Valve 6 1 No changes required
8


Need help? Post your question in this forum.

Forumrules
1

Forum

honeywell-cm727

Reset search

  • My heating is not coming on when I set it to the manual button Submitted on 26-5-2023 at 15:50

    Reply Report abuse
    • It may be because the room temperature is already at temp. Try turning the temp up and see if it fires. Answered on 27-5-2023 at 08:53

      Vote up Report abuse
  • When I set my thermostat to manual the heating doesn’t come on, where am I going wrong. Thank you Submitted on 26-5-2023 at 15:49

    Reply Report abuse
  • We’re going away for 4 weeks soon , I’ve set the Thermos on Auto to come on twice a day for an hour to prevent any freezing in the pipes- will the thermos still come on automatically between the set times if the temp drops below a certain level? In other words, will our heating be on full time when we’re away during a cold snap? Obviously this is going to incur high charges for us .Any advice appreciated Submitted on 12-12-2022 at 06:43

    Reply Report abuse
  • Hi I have a CM721 and CM727 Honeywell Thermostat.
    I cannot manage to keep the temperature to remain constant, IE At night I sometimes need 23 C to stay warm during the night ( otherwise I get cramp! )
    Which button/s do I press and in which sequence please ?
    Many Thanks,

    Alan
    Submitted on 15-11-2021 at 12:31

    Reply Report abuse
    • You’d have to leave the thermostat on manual and adjust the temperature with the up and down arrow buttons to the right hand side of the screen Answered on 15-11-2021 at 12:33

      Vote up Report abuse
  • Why does the heating come on outside of the times I have set it to come on, when in auto mode? Submitted on 3-11-2021 at 08:16

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell CM727 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell CM727 in the language / languages: English as an attachment in your email.

The manual is 0,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Honeywell CM727

Honeywell CM727 User Manual - English - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info