10 69-0865
11 69-0865
MARCHE: The fan runs continuously. Use for improved
air circulation during special occasions or for more
efficient electronic air cleaning.
AUTO: Normal setting for most homes and businesses.
The fan goes on and off with the cooling equipment
in the summer. In the winter, the fan on most sys-
tems starts a few minutes after the furnace comes
on. It stops a few minutes after the furnace goes
off. The fan starts and stops with the furnace in
some electric heat systems and with the compres-
sor in heat pump systems.
System Switch
System switching positions control thermostat opera-
tion as follows:
CHAUFF.: The thermostat controls your heating system.
REFROID.: The thermostat controls your cooling system.
ARRÊT: Both the heating and cooling systems are off.
You have finished programming your thermostat. If you
have removed it from the wall to program, replace it by
following the procedure. Read on to learn about the op-
erating flexibility of your thermostat.
Operating Your Thermostat
TEMPORARILY CHANGING THE PROGRAM
These features let you customize the program for
those times when you come home early, you are staying
up late, or you plan to be out for the evening. Changes
made with these keys are active for one program period
and then are canceled.
Keep Current Temperature Through the Next Period
Press and release SAUTER PROCHAINE PÉRIODE
key. The name of the period to be skipped will flash in
the display until the start time of the skipped period.
During the skipped period, the display will flash TEMP
to show that the programmed temperature for this pe-
riod is not being used.
Cooling Program
The program times are the same for both heating and
cooling. Program only the cooling temperatures if you have
already programmed for heating. To set times as you pro-
gram the cooling temperatures, use the AVANCER and
RECULER keys. But if you change the times for cooling,
you are also changing them for heating.
1. Move the system switch to the REFROID. position,
following the same instructions as for the heating pro-
gram.
2. After programming, adjust fan and system switches
as desired.
3. Press and release ACTIVER PROGRAMME key
to start the program.
SETTING SYSTEM AND FAN SWITCHES
Depending on your thermostat model, some of the
switch positions may not be available to you. Note the po-
sitions provided on your subbase and set the switch(es)
as desired.
Fan Switch
Fan switching positions are as follows:
To Go Back to the Temperature of the Previous Pro-
gram Period
Press and release REVENIR PÉRIODE
PRÉCÉDENTE key The display will show the name of
the previous period and flash TEMP until the next regu-
larly scheduled period starts.
To Temporarily Raise or Lower the Temperature for
the Current Period Only
Press and hold the +CHAUD or +FROID key until the
desired temperature is reached. The display will flash
TEMP until the next programmed time period starts.
If you change your mind
Press and release ACTIVER PROGRAMME key to
cancel any of the temporary settings.